Table 6. Unit Specifi Cations - Nordyne Air Conditioner / Heat Pump Air Handler Owner's Manual & Installation Instructions

E3 series (air conditioner / heat pump air handler) downflow, upflow electric furnaces
Table of Contents

Advertisement

Rated Heating Output, Btuh (see note 1)
Watts (Total kw, Heating Elements & Blower)
Supply Voltage
Heating Elements, No. (Total kw)
Blower Wheel Size
Motor Speed, H.P. Rating, Amps
Test ESP, in. w.c. Max
Optional Cooling Available with factory
installed blower
Optional Heat Pump Available with factory
installed blower
Air Filter (Standard)
Furnace Dimensions
1.
Heating output rated at listed voltage. For outputs at voltages other than 240V, multiply Btuh rating by the following factors: x 0.92 (230V),
x 0.84 (220V), x 0.75 (208V).
2.
Height is 56" with return air grille installed, 58" with coil cabinet and 72" with coil cabinet and upfl ow stand.
3.
The factory installed blower for the EB models can be replaced with a multi-speed blower allowing the units to accept up to 5 tons of air
conditioning.
ELECTRICAL INFORMATION
010H
012H
35,000
41,000
10.4
12.0
2 (10.0)
2 (11.6)
3 (15.0)
10.5" Dia,
10.5" Dia,
10.5" Dia,
8" W
8" W
2.0 - 4.0 Ton (See Note 3)
Width-20" (508mm), Height-29" (737mm) (see note 2), Depth-24 1/2" (623mm)
Table 6. Unit Specifi cations
Furnace Models E3EB-
015H
017H
020H
53,000
57,000
70,000
15.4
16.6
20.4
240 Volts/60Hz/1-Phase
3 (16.2)
4 (20.0)
10.5" Dia,
10.5" Dia,
8" W
8" W
8" W
4 Speed, 1/3 HP, 2.9
0.3
2.0 - 4.0 Ton
16" x 20" x 1" (nominal)
023H
023H 5-Ton
75,000
75,000
22.0
22.0
4 (21.6)
4 (21.6)
10.5" Dia,
11" Dia.,
8" W
8" W
4 Spd,
3/4HP, 3.8
Amps
2.0 - 5.0 Ton
19