Trigger Output1, Trigger Output2
Sets the TRIGGER OUT 1–2 jacks to function in sync with the power status of each zone
or input switching.

❑ Trigger Mode

Specifies the condition for the TRIGGER OUT jack to function.
Settings
The TRIGGER OUT jack functions in sync with the power status of the
Power (default)
zone specified with "Target Zone".
The TRIGGER OUT jack functions in sync with the input switching in
the zone specified with "Target Zone".
Source
An electronic signal is transmitted according to the setting made in
"Source."
Select this to manually switch the output level for electronic signal
Manual
transmission with "Manual".
Source
Specifies the output level of the electronic signal transmitted with each input, switching
when "Trigger Mode" is set to "Source".
Choices
AV 1–7, V-AUX, AUDIO 1–4, PHONO, TUNER, (network sources), USB, MULTI CH
Settings
Stops the electronic signal transmission when you switch to the input
Low
source specified in this option.
Transmits the electronic signal when you switch to the input source
High (default)
specified in this option.
Manual
Switches the output level for electronic signal transmission manually when "Trigger
Mode" is set to "Manual". This setting can also be used to confirm proper function of
the external device connected via the TRIGGER OUT jack.
Choices
Low
Stops the electronic signal transmission.
High (default)
Transmits the electronic signal.

❑ Target Zone

Specifies the zone with which the TRIGGER OUT jack functions are synchronized.
Settings
When "Trigger Mode" is set to "Power", electronic signal transmission
is synchronized with the power status of the main zone.
Main
When "Trigger Mode" is set to "Source", electronic signal transmission
is synchronized with the input switching in the main zone.
When "Trigger Mode" is set to "Power", electronic signal transmission
is synchronized with the power status of Zone2.
Zone2
When "Trigger Mode" is set to "Source", electronic signal transmission
is synchronized with the input switching in Zone2.
When "Trigger Mode" is set to "Power", electronic signal transmission
is synchronized with the power status of the main zone or Zone2.
All (default)
When "Trigger Mode" is set to "Source", electronic signal transmission
is synchronized with the input switching in the main zone or Zone2.

DC OUT

Configures the DC OUT jack setting.

❑ Power Mode

Selects how to supply power to the Yamaha AV accessory connected to the DC OUT
jack.
Settings
Supplies power through the DC OUT jack continuously regardless of
Continuous (default)
the power state (on/standby) of the unit.
Supplies power through the DC OUT jack only when the main zone is
Main Zone Power
turned on.
Sync.
(This setting may not work properly on some accessories.)
CONFIGURATIONS ➤ Configuring various functions (Setup menu)
115
En