H8DMT/H8DMT-IBX/H8DMT-F/H8DMT-IBXF User's Manual
Table 4-11. Hardware Health Monitor Submenu
Menu Item
CPU Overheat
Alarm
System Fan Monitor Submenu
Fan Speed
Control
FAN1 Speed
through FAN4
Reading
Other
Information
Menu Item
View BMC System
Event Log
Clear BMC
System Event Log
Set LAN
Configuration
IP Address
MAC Address
Subnet Mask
Set PEF Configuration Submenu
PEF Support
BMC Watch Dog
Timer Action
Description
Use the "+" and "-" keys to set the CPU temperature threshold to between 65
o
and 90
C. When this threshold is exceeded, the overheat LED on the chassis
will light up and an alarm will sound. The LED and alarm will turn off once the
CPU temperature has dropped to 5 degrees below the threshold set. The default
o
setting is 72
C.
This feature allows you to determine how the system will control the speed of the
onboard fans. Select W
Select S
if your system is used as a server. Select Disable to disable the
ERVER
fan speed control function to allow the onboard fans to continuously run at full
speed (12V). The options are 1) Disable (Full Speed) 2) 3-
3-
(W
).
PIN
ORKSTATION
The speeds of the onboard fans (in rpm) are displayed here.
Other items in the submenu are systems monitor displays for the following
information:
CPU1 T
, CPU2 T
EMPERATURE
T
, VC
EMPERATURE
ORE
VTT, CPU2 M
VTT, CPU1 M
EM
MCP55VC
, 1.5V and VBAT.
ORE
Table 4-12. IPMI Configuration
Description
Use the "+" and "-" keys to navigate through the system event log. Pressing the
Enter key will open the following setting:
Selecting this and pressing the Enter key will clear the BMC system event log.
Use the "+" and "-" keys to choose the desired channel number.
Use the "+" and "-" keys to select the parameter. The IP address and current IP
address in the BMC are shown.
Use the "+" and "-" keys to select the parameter. The MAC address and current
MAC address in the BMC are shown.
Use the "+" and "-" keys to select the parameter. The subnet address and current
subnet address in the BMC are shown.
Use this setting to E
NABLE
settings will appear:
This setting is used to set the Watch Dog function. The options are Disabled,
R
S
, P
ESET
YSTEM
OWER
if your system is used as a Workstation.
ORKSTATION
(for 2U systems), S
EMPERATURE
A, VC
B (for 2U systems), HT V
ORE
, CPU2 M
EM
EM
or Disable PEF support. When enabled, the following
D
and P
C
OWN
OWER
4-8
(S
PIN
ERVER
YSTEM
, CPU1 M
OLTAGE
, 12V, 3.3V, VDD, 5V VSB,
.
YCLE
o
) and 3)
EM

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8dmt-ibxfH8dmt-fH8dmt-ibx

Table of Contents