System Cooling; System Input Requirements; Operating Environment; Regulatory Compliance - Supero SUPERSERVER 5017C-MF User Manual

Superserver
Table of Contents

Advertisement

S
S
UPER
ERVER 5017C-MF User's Manual
Weight
Gross Weight: 18 lbs. (8.2 kg.)

System Cooling

Two 4-cm counter-rotating fans

System Input Requirements

AC Input Voltage: 100-240 VAC
Rated Input Current: 6.3A (115V) to 3.24A (230V)
Power Supply
Rated Output Power: 350W (Model# PWS-351-1H)
Rated Output Voltages: +3.3V (15A), +12
(29A), +5V (18A), +5Vsb (3A)
ALL

Operating Environment

Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)

Regulatory Compliance

Electromagnetic Emissions:
FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
Electromagnetic Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV
Certifi ed (Germany), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate"
B-2