Installing the Rack Rails
1. Determine where you want to place the 5017C-MF in the rack (see Rack and
Server Precautions in Section 2-3).
2. Position the fi xed rack rail/sliding rail guide assemblies at the desired location
in the rack, keeping the sliding rail guide facing the inside of the rack.
3. Screw the assembly securely to the rack using the brackets provided.
4. Attach the other assembly to the other side of the rack, making sure that both
are at the exact same height and with the rail guides facing inward.
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack.
1. Line up the rear of the chassis rails with the front of the rack rails.
2. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). See Figure
2-3.
3. When the server has been pushed completely into the rack, you should hear
the locking tabs "click".
Figure 2-2. Installing Chassis Rails
2-6