Download Print this page

Dynacord H 2500 Owner's Manual page 140

Powerh series power amps
Hide thumbs Also See for H 2500:

Advertisement

Available languages

Available languages

PowerH SERIES
RCM-26
NETWORK AND GENERAL FEATURES
Remote Control and Software
Maximum Configuration
Supervised Amplifier Parameters Operation mode, temperature, output voltage and current, impedance of connected speakers,
Network Supervision
Audio Monitoring
AUDIO SPECIFICATIONS
Analog Audio Input
Input Level (nominal)
Input Level (max. before clip)
A/D Conversion
Digital Audio Input
Input Sample Rates
Audio Output
Output Level (nominal)
Output Level (max. before clip)
D/A Conversion
Monitor Outputs
Frequency Response
Signal to Noise Ratio (A-weighted) ADC: 120 dB typical
THD+N
Signal Delay
Crosstalk
SIGNAL PROCESSING
Sample Rate
Data Format
Signal Processing
Master EQ (Input)
Master Delay (Input)
Channel EQ (Output)
X-Over
FIR Filters
Dynamics
Other Functions
Protection
INTERFACES
CAN
RS-232
GPIO Control Port
140
IRIS-Net™, Multiple PCs possible, MS Windows 98, 2000, XP
250 Amplifiers in total, 100 Amplifiers per CAN bus, 2000 meter cable run
protection mode status, mains voltage and current, power consumption, pilot tone detection
CAN bus failures, defective or missing amplifiers, bandwidth, failure protocol and messaging
All input and output signals
2 audio inputs on internal slot connector, pre-/post fader selectable
+6 dBu / 1.55 V
+21 dBu / 8.7 V
24 Bit linear, Sigma-Delta, 128 times over-sampling
AES3 (AES/EBU) format, XLR In/Thru connectors
32 kHz...192 kHz, internal Sample-Rate-Converter
2 audio outputs on internal slot connector
+6 dBu / 1.55 V
+21 dBu / 8.7 V
24 Bit, Sigma-Delta, 128 times over-sampling
2 x RJ-45 (REMOTE), electronically symmetric (Pins 7/8)
20 Hz...40 kHz (-1.0 dB)
DAC: 118 dB typical
AES3: 128 dB typical
Analog In to Analog Out: 116 dB typical
< 0.005%
1.031 ms @ 96 kHz
< -110 dB @ 1 kHz
96 kHz (48 kHz optional)
24 Bit linear A/D and D/A conversion, 48 Bit processing
2 DSPs (150 MHz, 300 MIPS)
6 filters per channel, selectable as PEQ, Lo-Shelf, Hi-Shelf, Hi-Pass and Lo-Pass
2...2000 ms per channel (units: µs, ms, m, inches, feet, samples)
6 filters per channel, selectable as PEQ, Lo-Shelf, Hi-Shelf, Hi-Pass, Lo-Pass and All-Pass
Hi-Pass and Lo-Pass per channel, 6/12/18/24 dB Bessel/Butterworth, 12/24 dB Linkwitz-Riley
Zero-Latency Processing, Linear Phase X-Over
Compressor and Limiter per channel
Input Routing, Level, Mute, Polarity, Sine and Noise Generator, Pilot Generator, Level Meters
Digital Speaker Protection
10...500 kbaud, 2 x RJ-45 (IRIS-Net™ Control)
9pin DSUB female (Multi-Media Control)
1 x 6-pole Euro block
2 Control Inputs
2 Control Outputs
2 Reference Outputs (+5 V, 200 mA / GND)

Advertisement

loading

This manual is also suitable for:

H5000