PowerH SERIES
During installation, always separate the power amplifier from the mains. Connect the power amplifier only
to a mains network, which corresponds to the requirements indicated on the type plate.
Device
H2500
H5000
Mains Operation & Resulting Temperature
The following tables allow the determination of power supply and cabling requirements. The power drawn
from the mains network is converted into output power to feed the connected loudspeaker systems and
into heat. The difference between power consumption and dispensed power is called power dissipation
(P
). The amount of heat resulting from power dissipation might remain inside of a rack-shelf and needs to
d
be diverted using appropriate measures. The following table is meant as auxiliary means for calculating
temperatures inside of a rack-shelf system/cabinet and the ventilation efforts necessary.
The column P
lists the leakage power in relation to different operational states. The column BTU/hr lists
d
the dispensed heat amount per hour.
H2500
Idle
Max. Output Power @ 8 Ω
Max. Output Power @ 4 Ω
1/3 Max. Output Power @ 4 Ω
1/8 Max. Output Power @ 4 Ω
1/8 Max. Output Power @ 4 Ω
1/8 Max. Output Power @ 4 Ω
Normal Mode (-10 dB) @ 4 Ω
Rated Output Power (0 dB) @ 4 Ω
Alert (Alarm) Mode (-3 dB) @ 4 Ω
Max. Output Power @ 2 Ω
1/8 Max. Output Power @ 2 Ω
1/8 Max. Output Power @ 2 Ω
10
Owner's Manual
Illustration 2.3: H2500/H5000 type plate
Voltage
100-240 V
100-240 V
Table 2.4: Specifications for the Power Supply Unit
U
in V
mains
230
3
230
3
230
3
230
3
230
4
230
4 5
253
3
230
3
230
3
230
3
230
3
230
4
230
Frequency
Power Consumption
50-60 Hz
1000 W
50-60 Hz
1450 W
I
in A
P
in W
P
mains
mains
out
0.7
70
15.3
2420
2 x 850
25.7
4300
2 x 1450
14.7
2325
2 x 483
6.2
875
2 x 181
6.7
1000
2 x 181
7.1
1105
2 x 219
5.6
775
2 x 145
23.5
3900
2 x 1200
16.7
2665
2 x 600
39.6
6920
2 x 2000
9.1
1345
2 x 238
9.1
1335
2 x 238
1
in W
2
P
in W
BTU/hr
d
-
70
239
720
2457
1400
4777
1358
4635
513
1749
588
2005
666
2274
485
1655
1500
5118
1465
4999
2920
9963
870
2969
860
2934