When Set For Incident Light - Sekonic L-608 Operating Manual

Exposure meter
Hide thumbs Also See for L-608:
Table of Contents

Advertisement

4. Basic Operation
4.

When set for incident light

1.
You can select extended or retracted lumisphere measuring positions by firmly rotating the
lumisphere retracting ring (UP/DOWN) until it clicks into position.
Extended Lumisphere
2.
When the Lumisphere is extended. (3-D Light Measurement)
This is used to photograph people, buildings, and other three dimensional objects.
Measurements are basically made by the method of measuring with the lumisphere aimed in
the camera direction (more precisely, in the direction of the lens axis) at the position of the
subject.
3.
When the Lumisphere is retracted (flat diffuser function)
This is used to photograph manuscripts, paintings or other flat copy. It can also be used for
measuring illumination levels (see page 27), or brightness difference (see page 25).
NOTE:
• If the device is used with the Lumisphere retracting ring in a middle position, distributed
light quality will change, and suitable measurements cannot be made.
• Do not push the Lumisphere down manually. Always use the Lumisphere retracting ring.
• If the lumisphere becomes soiled, wipe it with a soft, dry cloth. Organic solutions (paint
thinner, benzene, etc.) must not be used under any circumstances.
-10-
Retracted Lumisphere
(Lumidisc)