Mobile Home Requirements - Lopi Parlor Owner's Manual

Freestanding stove
Table of Contents

Advertisement

Stove Installation

Mobile Home Requirements

Outside air must be installed - see "Outside Air Requirements" on page 11
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model SSII chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
Minimum Clearance
(See the illustration above)
A
B
C
D
E
F
If using offsets, use the connector clearance listed in Figure 9,
not the connector manufacturer's clearance.
The appliance must be secured to the floor (consult your
building official). Secure the outside air boot to the floor and
stove to insure the stove does not dislocate.
Mobile home installations require a spark arrester at the
chimney termination.
The appliance must be grounded to the chassis of the mobile
home (consult your building official).
WARNING:DO NOT INSTALL IN SLEEPING ROOM.
CAUTION:THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
© Travis Industries
Straight Installations
d
e
a
b
NOTE:
Measure clearances to the stove top.
Sidewall to stove
Backwall to stove
Cornerwall to stove
Connector to sidewall
Connector to backwall
Connector to cornerwall
100-01141
(for qualified installers only)
Corner Installations
Reduced Clearance
Connector
18"
10-1/2"
9-3/4"
26-1/2"
11-1/4"
17-1/4"
f
c
Figure 8
12" Min.
Minimum Connector
Clearance
(as outlined above)
Minimum Stove
Clearance
(as outlined above)
4040923
13
Figure 9