Operation at 380-415V3N~: use a H05RR-
F five-wire cable (cable of 5 x 2.5 mm
Operation at 380-415V2N~: use a H05RR-
F four-wire cable (cable of 4 x 4 mm
Operation at 220-240 V~: use a H05RR-F /
H05RNF three-wire cable (cable of 3 x 6
2
mm
).
The earth wire (yellow-green) must be at
least 20 mm longer than the other wires at
the end for connection to the appliance.
The power supply cable must be fitted with a suitable five-pin plug (see
technical data plate) or, for appliances operating on 220-240V∼, a three-
pin plug. The power supply plug and wall socket must be of the same
type (in compliance with CEI standards). The appliance must be earthed
appropriately. Before connecting it, check that the power supply line is
properly earthed. The use of reductions, adapters or junctions is not
recommended.
The manufacturer cannot be held liable for damage to persons or
things caused by failure to comply with the above requirements or by
tampering with any part of the appliance.
2.2 Levelling
Level the appliance by means of its four adjustable feet. To make the
adjustment, undo the lock-nut and unscrew the foot. The adjuster screw
travel is 10 mm.
2.3 Instruction for wall fixing
8