Operation - Central Pneumatic 92359 Assembly And Operating Instructions Manual

Coil roofing nailer 11 gauge contractor series
Table of Contents

Advertisement

When unpacking, check to make sure all parts shown in the Parts List on page 13
are included. If any parts are missing or broken, please call Harbor Freight Tools at the
number on the cover of this manual as soon as possible.
For best service, you should incorporate an oiler, regulator, and inline filter, as
shown in the diagram below. Hoses, couplers, oilers, regulators, and filters are all avail-
able at Harbor Freight Tools.
TO
ROOFING
NAILER
Note: To connect this tool, we recommend you use the included quick connector. If an
oiler is not used, for smoother operation and to extend the life-span of the tool,
put 3-5 drops of pneumatic tool oil in the attached quick connector (1) before
each use.
Testing the Full Sequential Safety Trip Mechanism
Warning: Even though the nailer should be empty during this procedure,
ALWAYS point the nailer at a piece of scrap wood when testing.
1.
Make sure the tool is disconnected from the air supply.
2.
Completely empty the Nail Cannister (82) of nails.
3.
The Nailer should not fire if the nose is not depressed against the workpiece.
4.
Make sure the Trigger (47) and nose move freely, without sticking - see the illus-
tration on the following page.
SKU 92359
For technical questions, please call 1-800-444-3353.