4
Push up the M2 release levers. Since
the M2 release levers may be difficult
to move, push them up forcefully one
at a time.
Do not manually return the M2
release levers to their original
positions. They will return to their
original positions when the fusing
unit cover is closed.
When returning the M2 release
levers to their original positions, do not move them with your hand.
5
Push up the fusing unit cover, and
then pull out any misfed paper.
6
Pull out any misfed paper.
7
Pull inside cover M3 toward you to
open it, and then pull out any paper
caught in the fusing unit.