Figure 27. "Show Interfaces Dcbx Detail" - Continued - Dell Force10 MXL Deployment Manual

Deploying fcoe (fip snooping)
Hide thumbs Also See for Force10 MXL:
Table of Contents

Advertisement

Deploying FCoE (FIP Snooping) on Dell Force 10 MXL
Figure 27.
Local DCBX Status
-----------------
DCBX Operational Version is 0
DCBX Max Version Supported is 0
Sequence Number: 1
Acknowledgment Number: 1
Protocol State: In-Sync
Peer DCBX Status:
----------------
DCBX Operational Version is 0
DCBX Max Version Supported is 0
Sequence Number: 1
Acknowledgment Number: 1
Total DCBX Frames transmitted 9
Total DCBX Frames received 4
Total DCBX Frame errors 0
Total DCBX Frames unrecognized 11
The next command will show vital information on the DCBX established PFC configuration. Type:
interfaces pfc
detail. This command will show more specific detail about the configuration that has
been negotiated between the devices. In this example interface TenGigabitEthernet 0/3 is used as a
downlink to a host server and CNA installed in that system. Interface TenGigabitEthernet 0/52 is the
uplink into the top-of-rack FCF switch.
Some key items in these results will be Priority list is 3, Remote Willing status is: (this should be willing
enabled for the Host CNA, and willing is disabled for FCF Nexus switch. Other important items to not is
PFC DCBX Oper status:, FCOE TLV TX Status is enabled.