3-WIRE SYSTEM
CONNECTIONS
1. Loosen or remove
center terminal
Mock screw.
2. Connect
neutral wire (white or center wire) of power supply cord to the center, silver
colored terminal
screw of the terminal
block. Tighten
screw.
3. Connect
the other wires to outer terminal
block screws. Tighten screws.
4. Tighten
strain relief screws.
5. Insert tab of terminal
block cover into slot of dryer rear panel. Secure cover with hold=
down screw.
3
4
5
1. External
ground
connector
2. Neutral
grounding
wire (green/yellow)
3. Center silver-colored
terminal
block screw
4. Neutral wire (white or center wire)
5. 3/4 in. (1.9 cm) ULqisted
strain relief
WARNmNG: If converting
from a 4-wire electrical
system to a 3=wire, the ground strap
must be reconnected
to the terminal
block support to ground the dryer frame to the
neutral conductor.
4-W_RE SYSTEM
CONNECTmONS
1. Remove center terminal
block screw.
2. Connect
ground wire (green or bare) of power supply cord to external ground conductor
screw,
3. Connect
neutral wire (white or center wire) of power supply cord and appliance
ground
wire (green with yellow stripes) under central screw of the terminal
block.
4. Connect the other wires to outer terminal
block screws. Tighten
screws.
5. Tighten
strain relief screws.
6. Insert tab of terminal
block cover into slot of dryer rear panel. Secure cover with hold-down
screw.
I
............... _ ........
4
6
1. External
ground
connector
2. Green or bare copper
wire of power supply cord
3. 3/4 in. (1.9 cm) ULqisted
strain relief
4.Center
silver-colored
terminal
block screw
5 Grounding
wire (green/yellow)
6. Neutral wire (white or center wire)