DRYER VENTING
If an Exhaust
Hood
Cannot
be Used
The outside end of main vent should have a sweep elbow
directed downward.
l
24" rain.
12" min.
(610 rnm)
(305 ram)*
*Minimum
clearance above
any accumulation
of snow,
ice, or debris such as leaves
Multiple
Dryer Venting
A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 5663 I/min. (200 CFM)
of air per dryer. Large-capacity
lint screens of proper design
may be used in main vent if checked and cleaned frequently.
The room where the dryers are located should have make-up
air equal to or greater than CFM of all the dryers in the room.
Back-draft Damper Kit, Part No. 3391910, is available from
your distributor
and should be installed in the vent of each
dryer to keep exhausted air from returning
into dryers and to
keep exhaust in balance within main vent. Unobstructed
return
air openings are required.
Each vent should enter the main vent at an angle pointing in
the direction of the airflow. Vents entering from the opposite
side should be staggered to reduce the exhausted air from
interfering
with the other vents.
If main vent travels vertically through the roof, rather than
through wall, install a 180° sweep elbow on end of vent at least
2 ft. (610 mm) above surface of roof.
The opening in wall or roof shall have a diameter
:1/2" (13 mm)
larger than vent diameter. Vent should be centered in opening.
Do not install screening over end of vent for best performance.
The maximum angle of each vent entering the main vent
should be no more than 30 °.
Keep air openings
free of dry cleaning
fluid fumes.
Fumes
create
acids which,
when
drawn
through
the dryer
heating
units,
can damage
dryers
and items
being
dried.
A clean-out
cover should
be located
on the main vent
for
periodic
cleaning
of the vent system.
GAS SUPPLY CONNECTION
Make Gas Connection
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. Remove red cap from gas pipe on back of dryer.
2. Connect gas supply to dryer. Use a pipe thread compound
approved for the type of gas supplied. If flexible metal
tubing is used, be certain there are no kinks.
If necessary for service, open the toe panel. Use a puny
knife to press on the toe panel locks located near the two
ends of the toe panel. Pull downward
on the toe panel to
open. Toe panel is hinged at the bottom.
3. Open the shut-off valve in the gas supply line and make sure
the dryer has its own gas supply opened.
4. Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. Bubbles will show
a leak. Correct any leaks found.