Gas Dryer Power Hookup - Maytag MGD4200BG0 Installation Instructions Manual

Gas and electric dryers
Table of Contents

Advertisement

Available languages

Available languages

If using a replacement
power supply cord, it is recommended
that
you use Power Supply Cord Replacement
Part Number 8529008.
For further information, please reference service numbers located
in "Assistance
or Service" section of your "Use and Care Guide".
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding
conductor and a grounding
plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING-"
Improper connection of the equipment-
grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
GAS DRYER POWER HOOKUP
ELECTRICAL
REQUIREMENTS
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow
these instructions can result in death,
fire, or electrical
shock.
[] 120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is also recommended
that a separate circuit
serving only this dryer be provided.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction
or
breakdown,
grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor
and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance
with all local codes
and ordinances.
WARNING-"
improper connection of the equipment-
grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
GAS SUPPLY REQUIREMENTS
Explosion Hazard
Use a new CSA International approved
gas supply line.
install a shut=off valve,
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 13" (330 ram)water
column.
Examples
of a qualified
person include:
licensed heating
personnel,
authorized
gas company
personnel, and
authorized
service personnel.
Failure to do so can result in death, explosion, or fire.
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
[] Your dryer must have the correct burner for the type of gas in
your home. Burner information
is located on the rating plate in
the door well of your dryer. If this information does not agree
with the type of gas available, contact your dealer or call the
phone numbers referenced in the "Assistance
or Service"
section of your "Use and Care Guide".
LP Gas Conversion:
iMPORTANT:
Conversion must be made by a qualified
technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial
rating plate for use with a different
gas without consulting your gas company.
7