Mitsubishi Electric MXZ-2B20NA Installation Manual page 4

Split-type air conditioners
Hide thumbs Also See for MXZ-2B20NA:
Table of Contents

Advertisement

Available languages

Available languages

1=6. INSTALLATION
DIAGRAM
(D)
More than 100
mm (3.94 in.)
X
Open as a rule
(E)
MXZ-2B20NA
More than 500 mm
(j)
\
(19.69 in.) ifthe front
and
are open
both sides
the leak test, apply insulat- |
ing material tightly so that there is
]
no gap,
When the piping is to be at-
tached to a wail containing
metals
(tin plated) or metal netting,
use
a chemically
treated
wooden
piece 20 mm (7.9 in.) or thicker
between the wall and the piping
or wrap 7 to 8 turns of insulation
vinyl tape around the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump down before removing
the otd air conditioner.
Remake
flare according
to the dimension
for new refrigerant.
More than
100 mm (3.94 in.)
_More
than
200 mm (7.87 in.) if there are
obstacles
to both sides
_(F)
PARTS TO BE PROVIDED
AT YOUR SITE
(A) Power supply cord*
t
(B) Indoor/outdoor
unit connecting wire*
1
(C) Extension
pipe (Refer to t-4.)
t
(D) Wall hole cover
1
(E) Piping tape
t
Extension
drain hose
(or soft PVC hose, t5 mm (19/32
(F) in.)inner
diameter or hard PVC
t
pipe VP16)
Little
(G) Refrigeration
oil
amount
(H) Putty
t
(I)
Pipe fixing band
2 to 7
(J) Fixing screw for (I)
2 to 7
(K) Wall hole sleeve
I
Soft PVC hose, t5 mm (19/32 in.)
(L) innerdiameteror
hard PVC pipe
1
VP16 for drain socket
* Note:
Place indoor/outdoor
unit connecting wire (B) and
power supply cord (A) at least 1 m (39.4 in.) away
from the TV antenna
wire.
The "Q'ty" for (B) to (K) in the above table is quan-
tity to be used per indoor unit.
Open as a rule
More than 500 mm (19.69 in.) if the back,
both sides and top are open
More than 350 mm (13.78 in.)
Units should be installed by licensed contractor
according to local code requirements,
i
Outdoor
unit installation
,
835 (32.87)
I 166,
""
o__
_6.!_ 800 (19.69) "t
"_J_
Air inlet
/_4_Air
outlet
4-10(0.39) x 21(0.83) Oval holes
[Unit: mm (inch)]
1=7. MOUNTING ARRANGEMENT
OF DRAIN SOCKET
Please perform the drain piping work only when draining from one place.
1) Choose one hole to discharge
drain and install the drain socket to the hole.
2) Close the rest of the holes with the drain caps.
3) Connect a vinyl hose of 15 mm (19/32 in.) in the inside diameter on the market with the drain socket and lead drain.
Note:
Install the unit horizontally.
Do not use the drain socket in the cold regions. Drain may freeze and it makes the fan stop.
The outdoor unit produces
condensate
during the heating operation.
Select the installation
place to ensure to prevent the outdoor unitand/or
the grounds
from being wet by drain water or damaged
by frozen drain water.
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents