Frigidaire FGF312ASA Installation Instructions Manual page 6

30" gas range with electric ignition or standing pilot
Hide thumbs Also See for FGF312ASA:
Table of Contents

Advertisement

Grounding Instructions
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong grounding
wall receptacle to minimize the possibility of electric shock
hazard from this appliance.
The customer should have the
wall receptacle and circuit checked by a qualified electrician
to make sure the receptacle isproperly grounded and polarized.
Preferred Method
Under
knob to the LITE position. You will hear the igniter sparking.
The surface bumershould light when gas is available to the top
burner. Each burner should light within four (4) seconds in
normal operation after air has been purged from supply lines.
Visually check that burner has lit. Once the burner lights, the
control knob should be rotated out of the LITE position. There
are separate ignition devices for each burner. Try each knob
separately until all burner valves have been checked.
Note: Knob styles may vary from those pictured below.
',l,'-J
'
', ,,
Power Supl_ly
Grounding
Cord with
Type
3-Prong
Wall
Grounding
Receptacle
Plug
Where a standard two-prong wall receptacle is encountered,
itis the personal responsibility and obligation of the customer
to have it replaced with a properly grounded three-prong wall
receptacle.
J
Knob Used
Knob Used
withTwo
withLinear
Position Valve
Flow Valve
6b.
Standing
Pilot Surface
Burners
After range and supply line conduits have been carefully
checked for leaks, purge air from the system. The standing
pilots must be lit immediately, proceed as follows:
DO NOT, UNDER
ANY CIRCUMSTANCES,
CUT OR
1.
REMOVE THE THIRD (GROUND)
PRONG FROM THE
2.
POWER CORD.
This range is equipped
with either an electric
ignition
system or standing pilots. To determine which system
your range has, lift the cooktop.
Models with standing
pilots will have pilot cups as pictured in step 6b. Follow
the appropriate instructions for your model.
Operation
of Surface Burners
Venturi Style
6a. Electric
Ignition Surface Burners
Operation of electric igniters should be checked after range
and supply line connectors have been carefully checked for
leaks and range has been connected to electric power. To
check for proper lighting, push in and turn a surface burner
Raise the cooktop.
Light both pilots with a match. When both pilots are lit,
adjust the top pilot adjustment
until the pilots are
approximately
1/8" above the pilot cage with a very slight
yellow tip.
I
1/8" Above Pilot
Cage
CheckSurface
Burners
To checkfor proper lighting, push in and turn a surface burner
knob to the LITE position. Each burnershould
lightwithin four
(4) seconds in normal operation. Once the burner lights, the
knob should be rotated out of the LITE position. Try each knob
separately until all burner valves have been checked.
6