Frigidaire FGF312ASA Installation Instructions Manual page 5

30" gas range with electric ignition or standing pilot
Hide thumbs Also See for FGF312ASA:
Table of Contents

Advertisement

Gas connection for electric ignition models
Manual
Flare
Flexible
FlareUnion
Pressure
Shutoff
Union
Appliance
Adaptor
Regulator
Valve
/
Conduit
/
On_
_
_
__
_
Off
so ico
s.ut-o.
W!v E. r o n ion
mode.s
on.y
Besure lever isin the "On" positionwhen
installationiscomplete
Gas connection for pilot models
Manual
Flare
Flexible
FlareUnion
Pressure
Shutoff
Union
Appliance
Adaptor
Regulator
Valve_
_
Conduit
off
a) Install an external manual gas shut-off valve to gas supply
line in an easily-accessible
location outside of the range.
Be sure you know how and where to shut-off the gas
supply to the range.
b)
Install 1/2" flare union adapter to pressure regulator.
c)
Attach appliance conduit to flare union on regulator.
d)
Install flare union adapter to external manual shut-off
valve.
e)
Attach appliance conduit to flare union on shut-offvalve.
f)
Make sure service shut-offvalve on pressure regulator is
in "ON" position.
g)
Check forleaks. Turn the gas supply on to the range and
use a liquid leak detector at all joints and conduits to
check for leaks in the system.
Do not use a flame to check for gas leaks.
Checking
Manifold Gas Pressure
Disconnectthe range and itsindividual shut-offvalve from the
gas supply piping system during any pressure testing of that
system at test pressures greater than 14" of water column
pressure (approximately 1/2" psig).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column pressure
(approximately 1/2" psig).
If it should be necessary to check the manifold gas pressu re,
connect manometer (water gauge) or other pressure device to
the top burner right rear orifice. Using a rubber hose with inside
diameter of approximately
1/4," hold tubing down tight over
orifice. Turn burner valve on.
For an accurate pressure check have at least two (2) other top
burners burning. Be sure the gas supply (inlet) pressure is at
least one inch above specified range manifold pressure. The
gas supply pressure should never be over 14" water column.
When properly adjusted for Natural Gas the manifold pressure
is 4." (For LP/Propane Gas the manifold pressure is 10.")
5. Read electrical con nection details below and
connect
electricity
to range.
Before
servicing,
disconnect
electrical
supply at circuit breaker, fuse or power cord.
Electric Requirements: An individual, properly grounded and
polarized branch circuit protected by a 15 amp. circuit breaker
or time delay fuse. See serial plate for proper voltage.
Extension Cord Precautions:
Because of potential safety hazards undercertain conditions,
we strongly recommend
against the use of any extension
cord. However, if you still elect to use an extension cord, it is
absolutely necessary that it be a UL listed 3-wire grounding
type appliance extension cord and that the current carrying
rating of the cord in amperes be equivalent to or greater than
the branch circuit rating. Such extension cords are obtainable
through your local service organization.
PLEASE READ CAREFULLYt
For personal
safety, this product must be properly grounded.
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flf316asaFgf316asaFgf316aqa

Table of Contents