Download Print this page
Frigidaire FFGF3000MWA Installation Instructions Manual
Frigidaire FFGF3000MWA Installation Instructions Manual

Frigidaire FFGF3000MWA Installation Instructions Manual

30" gas range venturi models with electric ignition

Advertisement

Quick Links

iNSTALLATiON
AND SERVICE
MUST BE PERFORMED
BY A QUALIFIED
iNSTALLER.
iMPORTANT:
SAVE FOR LOCAL
ELECTRICAL
iNSPECTOR'S
USE.
READ AND SAVE THESE
iNSTRUCTiONS
FOR FUTURE
REFERENCE.
I_
if the information
in this manual
is not followed
exactly,
a fire
or explosion
may
result
causing
property
damage,
personal
injury or death.
FOR YOUR SAFETY:
m
Do not store or use gasoline
or other flammable
vapors
and liquids in the vicinity
of this or any other appliance.
WHAT TO DO iF YOU SMELL GAS:
. Do not try to light any appliance.
• Do nottouch
any electrical
switch;
do not use any phone
in your building.
. immediately
call your
gas supplier
from
a neighbor's
phone.
Follow
the gas supplier's
instructions.
. if you
cannot
reach
your
gas
supplier,
call
the
fire
department.
installation
and service
must be performed
by a qualified
installer, service
agency
or the gas supplier.
Refer to your serial plate for
applicable agency certification
e ALL RANGES
CAN TiP
• INJURYTO
PERSONS
COULD
RESULT
e iNSTALL
ANTI=TIP
DEVICE
PACKED
WiTH
RANGE
• SEE iNSTALLATiON
iNSTRUCTiONS
Note:
For appliances
installed
in the
Commonwealth
of Massachusetts
see
page 2.
OVERALL
253/4"
291/4"
incl. door
48"
Maximum
36 + 1/8"
\
463/8"
\-.
door open
29 7/8" _-_\
_
30"---*
14-13"-_1
Maximum Depth
j_
for Cabinets
Above Range Top, _
0" Clearance Below Cooking Top and at Rear of Range.
Clearances
and Dimensions
1.
LocationmCheck
location
where the rancLe will be
installed. Check for proper electrical
and gas supply,
and the stability
of the floor.
2.
Dimensions
that are shown
must be used. Given
dimensions
provide
minimum
clearance.
Contact
surface
must be solid and level.
Provide
Proper Fuel Type
Before
Proceeding:
Your range is preset to operate on
natural gas.
DO NOT attempt to convert this range to LP/
Propane settings without the proper LP/Propane conversion
kit provided with the range or obtained from your dealer. Follow
all instructions provided with the LP Conversion Kit.
pin 316469107 EN/SP (0810)
Espadol - Paginas 9-16

Advertisement

loading

Summary of Contents for Frigidaire FFGF3000MWA

  • Page 1 iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALIFIED iNSTALLER. iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE. READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE. if the information in this manual is not followed exactly, a fire or explosion result causing property damage,...
  • Page 2: Important Safety

    important Notes to the installer Never leave children alone or unattended Read all instructions contained in these installation in the area where an appliance is in use. As children grow, instructions before installing range. teach them the proper, safe use of all appliances. Never leave Remove all packing material from the oven compartments the oven door open when the range is unattended.
  • Page 3: Before Starting

    Locate the Bracket Using the Template- (Bracket may Before Starting be located on either the left or right side of the range. Use Tools You Will Need the information below to locate the bracket if template is For leveling legs and Anti=Tip Bracket: not available).
  • Page 4 Connect the range to the gas supply. Level and Position Range- Level range by adjusting the NOTE: To prevent leaks use pipe joint sealant on all male (4) leveling legs with a wrench. Note: A minimum clearance (outside) pipe threads. of 1/8"...
  • Page 5 the 1/2" flare union adapter with an adjustable wrench before tightening the gas supply fitting and/or appliance conduit (Refer to Fig. 4e). Install flare union adapter to external manual shut-offvalve. Attach appliance conduit to flare union on shut-off valve. Make sure service shut-off valve on pressure regulator is in the "ON"...
  • Page 6 5. Read these electrical connection details first Grounding Instructions then connect electricity to range. The power cord of this appliance is equipped with a Before servicing, disconnect electrical 3-prong (grounding) plug which mates with a standard supply at circuit breaker, fuse or power cord. 3-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance.
  • Page 7 Operation of Surface Burners Burner Baffle Operation of electric igniters should be checked after range and 1" Flame supply line connectors have been carefully checked for leaks and range has been connected to electric power. Check Surface Burners To check for proper lighting, push in and turn a surface burner knob to the LITE position.
  • Page 8 Model and Serial Number Location The serial plate is located under the lift=up cooktop. When ordering parts for or making inquires about your range, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your range. Your serial plate also tells you the rating of the burners, the type of fuel and the pressure the range was adjusted for when it left the factory.

This manual is also suitable for:

Xflf3005lwbXflf3005lqbFfgf3011lbcFfgf3011lwcXfgf3005lqbXfgf3005lwb ... Show all