External Frost Protection - Biasi RIVA COMPACT HE M96.24SM/C2 User Manual And Installation Instructions

Wall hung, fan flue, room sealed, high efficiency gas boiler
Table of Contents

Advertisement

Installation
L
Fig. 6.12
For the electrical connection to the boiler use elec-
tric wires which conform to the current regulations,
with flexible cord, each core having a cross sec-
tion area not less than 0,75 mm
6 Connect the electrical supply flexible cord
coming from the fused spur isolation switch to
the power supply terminal block of the boiler
(Fig. 6.13) keeping the same connections for
the live (brown wire) and the neutral (blue
wire). External 3 A fuse or fused plug with same
current rating is recommended.
Do not connect live wires to terminals to
which the room thermostat must be con-
nected.
7 Connect the earth wire (yellow/green).
Connection of a room thermostat
The room thermostat must be connected to the
terminal block situated next to the control panel.
When connecting any type of external control,
the link M in Fig. 6.13 must be removed.
To fused spur
isolation switch
3
2
1
M
Fig. 6.13
30
2
.
L
N
Power supply
terminal block
External controls
terminal block
8 Connect the room thermostat between ter-
minals 1 and 3 as shown in Fig. 6.14.
Do not connect live wires to terminals to
which the room thermostat must be con-
nected.
Room thermostat
T
3
2
1
Fig. 6.14
9 Route the electrical supply flexible cord and
the external control flexible cord as illustrated
in Fig. 6.15.
Lock the flexible cords in place with the flexible
cord clamps
To the external
control device
Fig. 6.15
6.10

External frost protection

10 Connect the frost thermostat between ter-
minals 1 and 2 as shown in Fig. 6.16.
Do not connect live wires to terminals to
which the room thermostat must be con-
nected.
Power supply
terminal block
L
N
External controls
terminal block
To the fused spur
isolation switch