6.10 External Frost Protection - Biasi RIVA PLUS HE 24S ERP User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

• Connect the room thermostat between ter-
minals 1 and 3 as shown in Fig. 6.17 or
Fig. 6.18.
T
Room thermostat
(230V rating)
L
3
2
1
Fig. 6.17
Room thermostat
T
with delay resistor
(230V rating)
L
3
2
1
External controls
terminal block
Fig. 6.18
• Route the electrical supply flexible cord
and the external control flexible cord as
illustrated in Fig. 6.19. Lock the flexible
cords in place with the flexible cord clamps
- 38 -
INSTALLATION
N
Power supply
terminal block
External controls
terminal block
N
Power supply
terminal block
To the external
control device
Fig. 6.19

6.10 External frost protection

• Connect the frost thermostat between ter-
minals 1 and 2 as shown in Fig. 6.20 or
Fig. 6.21. Do not connect live wires to
terminals to which the room thermostat
must be connected.
Frost Thermostat
T
(230V rating)
External controls
terminal block
Fig. 6.20
To the fused
spur isolation
switch
Room thermostat
T
(230V rating)
L
N
3 2 1
Power supply
terminal bloc k

Advertisement

Table of Contents
loading

This manual is also suitable for:

Riva plus he 28s erp

Table of Contents