Technical Data Mod. M96.24Sm - Biasi RIVA COMPACT HE M96.24SM/C2 User Manual And Installation Instructions

Wall hung, fan flue, room sealed, high efficiency gas boiler
Table of Contents

Advertisement

Technical information
4.5
Technical data
mod. M96.24SM/...
(A)
Heat input
Nominal
Minimum
Useful output G20
Maximum
Minimum
Maximum condensing
Minimum condensing
Useful output G30 G31
Maximum
Minimum
Maximum condensing
Minimum condensing
(A)
referred to the net calorific value at 15 ûC and 1013,25 mbar
3,
G 20 = 34,02 MJ/m
(B)
The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating
of dwellings. The test data from which it has been calculated have been certified by a notified body.
(C)
Values subject to tolerance
kW
25,0
BTU/h
85 295
kW
11,0
BTU/h
37 530
kW
24,6
BTU/h
83 973
kW
10,2
BTU/h
34 936
kW
26,6
BTU/h
90 754
kW
11,1
BTU/h
37 871
kW
23,7
BTU/h
80 894
kW
10,2
BTU/h
34 936
kW
26,6
BTU/h
90 754
kW
10,8
BTU/h
36 997
G 30 = 45,6 MJ/kg, G 31 = 46,4 MJ/kg
Central heating
Maximum flow temp.
Minimum flow temp.
Minimum return temp.
Maximum pressure
Minimum pressure
Available head
(in 1000 l/h)
Seasonal efficiency
(B)
G20
Seasonal efficiency
(B)
G30 G31
Domestic hot water
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Flow rate
minimum
(C)
30û rise
(C)
35û rise
(C)
40û rise
Gas supply pressures
Gas
Natural
G20
Norm.
Pa
2 000
mbar
Max
Pa
2 500
mbar
Min.
Pa
1 700
mbar
1 mbar approximately equals 10 mm H
ûC
85
ûC
38
ûC
30
kPa
250
bar
2,5
kPa
30
bar
0,3
kPa
25
bar
0,25
band
%
87,7
band
%
87,0
ûC
55
ûC
35
kPa
1 000
bar
kPa
30
bar
0,3
l/min
2,5
l/min
12,1
l/min
10,1
l/min
8,7
Butane
Propane
G30
G31
2 900
3 700
20
29
3 500
4 500
25
35
2 000
2 500
17
20
O
2
B
B
10
37
45
25
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents