General Specifications; Notice Special Requirements; Inspect/Prepare Installation Site; Clearances To Burner And Appliance - Beckett AFII85 Installation Manual

Oil burner afii series types 'hlx' & 'fbx' air tube combinations voltage: 120 volts ac/60 hz
Table of Contents

Advertisement

Genera|
information
• General
Specification
Table 1 - Burner
Specifications
Capacity
'HLX' Heads
Firing rate:
- 0.40 - 1.50 GPH
Input: Min./Max
- 56,000/210,000
Btu/h
'FBX' Heads
Firing rate:
- 0.40 - 1.35 GPH
Input: Min./Max. - 56,000/189,000
Btu/h
Certification/
UL certified to comply with ANSI/UL296
&
Approvals
tested to CSA B140.0
Fuels
U. S No. 1 or No. 2 heating oil only (ASTM
D396)
Canada No. 1 stove oil or No. 2 furnace oil
only
Electrical
Power supply - 120 volts AC, 60 Hz, single
phase
Operating load - 5.8 Amps max
Motor
- 1/7 hp, 3450 rpm, NEMA 48M
frame PSC rotation CCW when
facing shaft end
Ignition - Continuous duty solid-state igniter
Fuel pump
Outlet pressure - Note 1
Air tube
ATC code
- See Table 2
Dimensions
Height (maximum)
-
13 inches
(with cover)
Width (maximum)
- 14 inches
Depth
- 6-11/16 inches
Air tube diameter
3-1/2 inches
• Notice
Special
Requirements
For recommended
installation practice in Canada,
refer to the latest version of CSA Standard B139 &
B140.
Concealed damage -- If you discover damage to
the burner or controls during unpacking, notify the
carrier at once and file the appropriate claim.
When contacting Beckett for service information --
Please record the burner serial number (and have
available when calling or writing). You will find the
serial number on the silver label located on the left
rear of the burner. Refer to Figure 1.
inspect/Prepare
installation
Site
, Clearances
to Burner and Appliance
Provide space around burner and appliance
for
ease of service and maintenance. Check the mini-
mum clearances
against those shown by the ap-
pliance manufacturer
and by applicable
building
codes.
*Note 1. See appliance manufacturer's burner specifications for
recommended outlet pressure.
Table 2 - Air Tube Combinations
(ATC)
& Dimensions
ATC codes for usable air tube lengths dim. "A" (Figure 3)
Firing rate range (gph)Min-Max
3"
5"
7"
9"
ATC Code
Head
AFII 85
AFII 100
AFII 150
-u
HLX30
HLX50
HLX70
HLX90
HB
AF2-6
0.4-0.85 gph
0.65-1.00 gph
0.75-1.35 gph
_e o_ e _-
HLX30
HLX50
HLX70
HLX90
HC
AF2-9
N/A
0.65-1.00 gph
0.75-1.50 gph
_
OI
ob
"d
HLX30
HLX50
HLX70
HLX90
HD
AF2-6
0.40-0.85 gph
0.65-1.00 gph
0.75-1.10 gph
o
HLX30
HLX50
HLX70
HLX90
HE
AF2-9
N/A
0.65-1.00 gph
0.75-1.35 gph
_-
FBX30
FBX50
FBX70
FBX90
HFXS
FB0
0.40-0.65 gph
0.55-0.75 gph
0.75-1.00 gph
-o
FBX30
FBX50
FBX70
FBX90
HGXS
FB3
0.55-0.85 gph
0.55-1.10 gph
0.85-1.20 gph
-u _
FBX30
FBX50
FBX70
FBX90
HHXS
FB4
N/A
0.75-1.10 gph
1.10-1.25 gph
®
FBX30
FBX50
FBX70
FBX90
HIXS
FB6
N/A
0.85-1.15 gph
1.15-1.35 gph
I
HB 6 slot
'!
1
HC 9 slot
3-5/32"
I
I
I,D,
]_
2-15/16"
I.D.
1
HD 6 slot
HE 9 slot
RWB 6104 BAFII R01
Page 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afii100Afii150

Table of Contents