General Specifications; Notice Special Requirements; Lnspectlprepare Installation Site; Clearances To Burner And Appliance - Beckett NX50LG Manual

Nx series oil burner
Table of Contents

Advertisement

Genera|
information
• General
Specifications
Table 1 - Burner
Specifications
Capacity
Firing rate: - 0.40 - 1.75 GPH
Input: Min. - 56,000
Btu
Max - 245,000 Btu
Certification/
UL certified to comply with ANSI/UL296
&
Approvals
tested to CSA B140.0
Fuels
U. S No. 1 or No. 2 heating oil only (ASTM
D396)
Canada No. 1 stove oil or No. 2 furnace oil
only
Electrical
Power supply - 120 volts AC, 60 Hz, single
phase
Operating load - 5.8 Amps max
Motor
- 1/7 hp, 3450 rpm, NEMA 48M
frame PSC rotation CCW when
facing shaft end
Ignition - Continuous duty solid-state igniter
Fuel pump
Outlet pressure - Note 1
Air tube
ATC code
- See Table 2
Dimensions
Height (maximum)
- 12-1/2 inches
(with cover)
Width (maximum)
15 inches
Depth
9-1/4 inches
Air tube diameter
3-1/4 inches
*Note 1. See appfiance manufacturer's burner specifications for
recommended outlet pressure.
Table 2 - Air Tube Combinations
(ATC)
Firing rate
Head
ATC codes for usable air tube
(gph)
lengths:
(min-max)
5"
7"
9"
0.40-1.00
9-Stot
NX50LG
0.40-1.00
6-Slot
NX50LH
0.40-1.35
9-Slot
NX50LB
0.40-1.35
6-Stot
NX50LC
1.10-1.75
9-Stot
NX50LD
1.10-1.75
6-Stot
NX50LF
NX70LG
NX50LH
NX70LB
NX70LC
NX70LD
NX70LF
NX90LG
NX90LH
NX90LB
NX90LC
NX90LD
NX90LF
Figure 1. Burner
label location
• Notice Special
Requirements
For recommended
installation practice in Canada,
refer to the latest version of CSA Standard B139 &
B140.
Concealed damage -- If you discover damage to
the burner or controls during unpacking, notify the
carrier at once and file the appropriate claim.
When contacting Beckett for service information --
Please record the burner serial number (and have
available when calling or writing). You will find the
serial number on the silver label located on the left
rear of the burner. Refer to Figure 1.
inspect/Prepare
installation
Site
• Clearances
to Burner
and Appliance
Provide space around burner and appliance
for
ease of service and maintenance. Check the mini-
mum clearances
against those shown by the ap-
pliance manufacturer
and by applicable
building
codes.
• inspect Chimney
or Direct Vent System
Adequate
Combustion
and Ventilation
Air Supply
Required
Failure
to provide
adequate
air supply
could
se-
riously
affect the burner performance
and result
in damage
to the equipment,
asphyxiation,
ex=
piosion
or fire hazards.
The burner cannot properly
burn the fuel if it is not
supplied
with a reliable
combustion
air source.
Follow the guidelines
in the latest editions
of the
NFPA 31 and CSA-B139
regarding
providing
ad-
equate
air for combustion
and ventilation.
Inspect the chimney or vent. Make sure it is prop-
erly sized and in good working condition. Follow the
instructions supplied by the appliance manufactur-
er.
Page 4
General model
Informotion
Sedol number,
including
date
code
Rating
Informotion
Approval
agency
symbols
Primury
group
and fuel oil
--
Model " NX"
Series 0il Burner
SERIAL NUMBER
--
000405-62756
I(lllltllltBIIIII
--
C _)
US LISTED
BURRER NO. pHO0_01
R.W.Beckett
Corp.
.P 1_
xx6ce_
MFR'S
SETTINGS
me;
_xTm_
XX0000 R00
000405-62756
\
--
R.W. Beckett
monufocturer's
settings
--
R.W. Beckett
specification
number
(_nd revision
_-Con
be
customized
by
individuol
specification
SK9675
RWB 6104 BNX R02