Connect Fuel Lines; Start The Burner And Set Combustion; Startup Burner - Beckett AFII85 Installation Manual

Oil burner afii series types 'hlx' & 'fbx' air tube combinations voltage: 120 volts ac/60 hz
Table of Contents

Advertisement

Start
the
Burner
and Set Combustion
• Connect
Fuel Lines
Do Not Install
By=pass
Plug
with
1-Pipe
System
Failure
to comply
could
cause immediate
pump
seal failure,
pressurized
oil leakage
and the po-
tential
for a fire and injury
hazard.
The R7184 primary control with valve-on delay and
burner motor-off delay, shown in Figure 4, requires
a constant 120 volt AC power source supplied to
the black wire on the control. (Refer to the appli-
ance
manufacturer's
instructions.
The red wire
goes to the appliance limit circuit. Please note that
other control manufacturers
may use different wire
colors for power and limit connections.
The burner is shipped without the by-pass plug in-
stalled.
Install the by-pass plug in two-pipe oil supply systems
ONLY.
Start the Burner
and Set Combustion
Startup
burner
The burner is supplied with either a one-stage
pump or a two-stage pump based on the oil supply
system requirements.
Consult the instructions pro-
vided with the pump for installation specifications.
-&CAUTION
Oil Supply
Pressure
B_
Control
Required
Damage
to the filter or pump
seals
could
cause
oil leakage
and a fire hazard.
The oil supply inlet pressure to the burner cannot
exceed 3 psig.
Insure that a pressure limiting device is installed
in accordance with the latest edition of NFPA 31.
Gravity
Feed Systems: Always
install an anit-
siphon valve in the oil supply line or a solenoid
valve (RWB Part # 2182602U)
in the pump/noz-
zle discharge tubing to provide backup oil flow
cut-off protection.
When installing a one-pipe
system,
connect the
inlet line to the pump inlet. The fuel pump may be
Explosion
and Fire Hazard
Failure
to follow these instructions
could lead to equipment
malfunc-
tion and result
in heavy
smoke
emission,
soot=up,
hot gas puff-
back,
fire and asphyxiation
hazards.
Do not attempt to start the burner when excess oil
has accumulated
in the appliance, the appliance
is full of vapor, or when the combustion chamber
is very hot.
Do not attempt to re-establish
flame with the
burner running if the flame becomes extinguished
during start-up, venting, or adjustment.
Vaz0or-Filled Aoj01iance: Allow the unit to cool off
and all vapors to dissipate before attempting an-
other start.
Oil=Flooded A
liance: Shut off the electrical
power and the oil supply to the burner and then
clear all accumulated oil before continuing.
If the condition still appears unsafe, contact the
Fire Department. Carefully follow their directions.
Keep a fire extinguisher
nearby and ready for
use.
installed with gravity feed or lift. The maximum al-
lowable lift for a single pipe installation is 8 ft.
When installing a two-pipe
system,
remove the
1/16" pipe by-pass plug from plastic bag attached
to fuel unit.
Remove 1/4" plug from return port.
Insert and tighten the by-pass plug. Attach return
and inlet lines. The return line should terminate ap-
proximately 3 to 4 inches above supply line inlet.
Failure to do this may introduce air into the system
and could result in loss of prime.
Wiring
Connections
Diagram
Refer to the appliance manufacturer's
wiring dia-
gram prior to connecting the burner wiring. All wir-
ing must be in accordance with the latest revision of
National Electric Code NFPA 70 and all local codes
and regulations.
1. Open the shutoff valves in the oil supply line to
the burner.
2. Open the air dial. This is an initial air setting for
the pump bleeding procedure only. Additional ad-
justments must be made with instruments.
3. Set the thermostat substantially above room tem-
perature.
.
Close the line voltage switch to start the burner.
If the burner does not start immediately you may
have to reset the safety switch of the burner pri-
mary control.
.
Bleed air from the fuel unit as soon as burner mo-
tor starts rotating. To bleed the fuel unit, attach
a clear plastic hose over the vent fitting. Loosen
the fitting and catch the oil in an empty container.
Tighten the fitting when all air has been purged
from the oil supply system.