305cm
(12-)
30,5 an
(12 _)
outside
wall
ext_eur
Exhaust requirements,
cont.
Do Notuse plastic or metal foil vent.
Flexible metal vent must be fully extended and supported when
the dryer is in its final position. Remove excess flexible vent to
avoid sagging and kinking that may result in reduced air flow•
An exhaust hood (A) should cap the exhaust vent to prevent
exhausted air from returning m the dryer.
Exhaust outlet hood must be at least 30.5 em (12 inches) from
the ground or any object that may be in the path of the exhaust
(such as flowers, rocks or bushes, etc.).
ff using an existing exhaust system, clean tint from entire
lengthof systemandmake sure exhausthood is not pluggedwith
lint.Replace anyplasticor metal foilventwith rigid metal or
flexiblemetalvent.
Use clamps to sealaUjoints.Do Notuse duct tspe,serewsor
otherfasteningdevicesthat extend into the interior ofthe ventto
secure
vunt.
Service check: Bach pressure in any exhaust system used must
not exceed 1.5 em (0.6 inches) in water column measured with
an incline manometer at the point that exhaust vent connects to
dryer.
Mobile home installation
requirements
The dryer must be exhausted outside.
Theexhaustventmustbe securely fastenedto a non-combu_le
portion ofthe mobile home structure andmust not terminate
beneaththe mobile home.
Exigences de ddcharge, suite
Nepas utiliserun conduit m6tallis_ou de plastique.
Unconduit m_tallique flexible doit _tre totalement d_loy_ et
suutenu lorsqueh s_cheuseestit sa positionfinale.Eulevertout
exc_sde conduitflexiblepour&itcr toutaffaJssemenl/d_formatiun
susceptiblede r_duirela eapadt_d'@acuatiun.
Terminer le conduit d'_vaenatlon parun dspet de d&haxge(A)
qui emp_cherale retourversla s_cheusede Fairexpuls&
Ledapet de d&harge doit_lre situ__L au moins 30,5 em
(12 punces) au-dessus du sol ou de toutautce objetsusceptiblede
se trouversur le tcajetde Fairhumide rejet_(parexemplefleurs,
roches ou arbustes, etc.)
Lot'sde l'uttlisation d'un systhne de d&harge _t,
netinyeret eqiminerla chaxpiesur toutela longueur du systhne et
veillerk ce que le &pet de d_chasgene suit pas obstm_par une
accumulationde chaxpie.Remplacertoutconduit mCqallls_ o u de
plaxtiquepar un conduitm6tallique flexibleou rigide.
utiliser des brides pour scellertousles joints.Nepas uUllser de
rubenadh_sffpourconduit, desvis ou auttesdispositifsde fixation
qui se prolungent _L l'int6rieur du conduit pour fixercelui-ci.
Contr61e du fonctlonnement : Lar&copressiun g_a_'de par un
systhne de d6charge ne doit pas d6passer1,5 em (0,6 pouce)
colunne d'eau,ceci _tantmesur_axecun manom_'e appropri_ au
point de raccordement d u conduit _la s_cheuse.
Exigences concernant l'installation
darts une
r_sidence mobile
Lad&harge de la s&heuse deit _tre refi_e _tl'ext_rieur.
Leconduit d'&acuatiun doit _t_efix_solidement_une paxtienon
combustible de la structure de l'habitationmobile etne pas se
terminer suus l'habitatiun mobile•
Plan the exhaust vent installation
Route the vent
The exhaust outlet is locatedatthe center of the rear ofthe
dryer.
The exhaust vent can be routcd up, down, lell, right or straight
out the back of the dryer. See "Recessed area/closet installation"
section, Page 3, for space requirements.
Planification
de I'installation
du circuit
de d6charge
Itin_raire du conduit
Labouche de d&harge est situ_e_ l'arri_rede la sdcheuseau
centre.
Onpent acheminer le conduit d'_vaenntionparle haut, par le bas,
par la gauche, pas la droite,ou en lignedroitedepuisl'arri_re de h
s_cheuse.Voir,,Installationdunsun placardon un encastcemunt'h
page 3, pourles exigencesd'esparement.
Select the route that will provide the straightest and most
direct path outdoors. Phn the installationto use the fewest
number of elbowsand turns.Avoidmaking90° turns.
When using elbows or making turns, allow as much room as
possible. Bend vent
gradually
to avoid kinking.
ChoiMrl'itin_mire d'arheminement vet's Fe_eur
qui
sera le plus direct et le plus rectiligne, elanillerl'installafiun
pour intcoduirele nombre minimum de coudes et chengements
de directionl_viter les chungementsde directioniL90°
Si des coudes sont uttlis_s pour les chang_ents
de
direction, pr&oir autuntd'espaceque c'est possible•Pher le
conduit graduellemempour &iter de le d_former.
Preferred
--
Preferable
--
Maximum length of 10.2 an (4") dtmneter metalvent
Longueur maximum de conduit
m_t alltque de 102 n-ma (4 po)
Number of
Rigid
Flexible
90" dhows
Conduit rigide
(fully extended)
Nombre de
Conduitflexible
coudes it 90 °
(c_pl_ent
d_ploy_)
0
19.5 m (64 ft.) 19,5 m (64 pi)
11.0 m (_6 ft.) 11,0 m O6 pi)
1
16.5 m (54 ft.) 16,5 m (54 pi)
9.4m (31 ft.) 9,4m (31p0
2
13.4 m (44 ft.) 13,4 m (44 pi)
S.2 m (27 ft.) S,2 m (27 pi)
3
10.7 m (_5 ft.) 10,7 m (35 pO
7.6m (25 ft.) 7,6m (25 p0
4
S.2 m (27 ft.) S,2 m (27 p0
7.0 m (23 ft.) 7,0 m (23 p0
Acceptable
i
Acceptable
i
[]--_II)
1_6,4_m(Z-_Zpo)
Mmdmum length of 10.2 c_ (4") diameter metalvent
Longueur maximum de conduit m_qallique
de 10Zmm (4po)
Number of
Rigid
Flexible
90" dhows
Conduit rigide
(fully extended)
Nombre de
Conduitflexible
coudes _ 90 °
(cmpl_ement
d_ploy_)
0
17.7 m (58 ft.) 17,7 m (58 p0
S.5 m (2Sfi.) S,5 m (2Sp0
1
14.6 m (48 ft.) 14,6 m (48 pi)
7.0 m (2_ ft.) 7,0 m (2_ pi)
2
11.6 m (38 ft.) 11,6 m (3S pi)
5.8 m (19 ft.) 5,S m (19 pi)
3
8.S m (29 ft.) 8,8 m (29 pi)
5.2 m (17ft.) 5,2 m (17pi)
4
6.4 m (21 ft.) 6,4 m (21 pi)
4.6m (15 ft.) 4,6m (15 p0
Determine
exhaust vent length
The maximum length of the exhaust systemdependsupon:
-- the typeofvent(rigid or flexiblemetal).
-- the number of elbowsused.
1.See the exhaustventlength chart that matchesyour typehood
for the maximumventlengthsyou can use.
Do not use vent runs longer than specified in exhaust
vent length charts.
Exhaust s ystemslonger than specifiedwill:
-- Accumulatetint creating a potential f ire
hazard.
-- Shorten the life ofthe dryer.
-- Reduce performance, resultingin longer
dryingtimes and increased energyusage.
2. Determine the number of elbowsyouwill need.
3. in the column listingthe typeofmetal ventyou are using (rigid
or flexible),findthe maximumlengthof metal venton the
samefine as the number of elbows.
4. Determine the numberof 10.2 can(4 inch) dampsyou will
need.
The maximum length using a 5.1 crux 15.2 cm (2" x 6")
rectangular vent with 2 elbows and a 6.4 cm (2 -1/2")
exhaust hood is 2.4 m (8 ft.).
For exhaust systems not covered by exhaust vent length
charts (such as multiple unit hookups, plenums,andpower-
assistfans),see Service Manual, P artNo.603197. (Topurchase
the ServiceManual, s ee yourUse andCareGuidefor atoll-free
telephonenumber.)
Longueur du conduit
La longueur mmdmum du circuit d'&acuatiun d£'pend de
plnsieurs faztcurs:
-- le typede eunduit(m_talrigideou flexible).
-- le nombrede eoudesincorpur_s au circuit.
2.
3.
Consulterle tableaucorrespundunt au typede clapetde deehasge
ulilis_pour d6terminer h longueurmaximumde eonduit
utifisable.
Ne pus installer un conduit de longueur sup_rieure _tla
valeur sp&ifi_e dans le tableau.
Si h lungueurdu circuit est sup_rieure _ h valeursp&ifi_edens
le tableau,on observera :
-- Accumulationde charpie et risqued'incendie.
-- Rdductiunde la long&it_ de la s_cheuse.
-- Rdductiunde la performance, a xectemps de s_chageplus
long et plus grende consommatiund'_nergie.
D_m-minerle nombre de coudes n_cessatres.
Dens la colunne correspundunt autypede conduit m_talllque
utills_ (rigide ou flexible),identifier la longueur maximumde
conduit m6talliquesurla llgne correspundam au hombre de
coudes.
4. D_terminerle nombre de brides de 102 mm (4 po) n6cessaires.
Pour une installation faite de conduits rec_sugulaires de
51 mm x 152 mm (2 po x 6 po) et comportant 2 coudes et
un dapet de d&harge de 64 mm (2-1/2 po), la longueur
maximum de eonduit est 2,4 m (8 pi).
Pour un circuit de d&harge qui n'est pus couvert par les
tableaux (par exemplesyst_e avec raccordement d e phsieurs
s_eheuses,pleura et syst&nesaveeventilateur), consulter le manuel
de service,a_ide n° 603197. (Pour l'achat du manuel de service,
trouver le num_ro d'appel sans frais dam le Guided'uifiisatiunet
d'entretien).