30" (76.2 cm) slide-in dual fuel ranges
Hide thumbs Also See for JDS8850CDB01:

Advertisement

Available languages

Available languages

Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing the
range is adequate as long as it conforms to the standards
listed above.
Product Dimensions
A
B
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination
above the range, follow the range hood or
microwave hood combination
installation instructions for
dimensional clearances above the cooktop surface.
Range may be installed with zero clearance to combustible
construction
at the rear and on the sides below the cooktop.
F
D
F
A. 303/4" (78.1
cm)
B. 353/4 '' (90.8 cm) height
to underside
of cooktop
edge
with
levering
legs
screwed
aft the way in*
C. Model/serial
number
plate
(located
behind
the storage
drawer
on the
right-hand
side of the oven
frame)
E
G.
297/8" (75.9 cm)
Gas information
plate
(located behind the
warming drawer on the
left-hand
side of oven
frame)
291/16 '' (73.8 cm) from
handle to back of range**
23V2" (59.7 cm)
countertop
notch to rear
of cooktop
*Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
**When installed in a 24" (61.0 cm) base cabinet with
25" (63.5 cm) countertop; front of oven door protrudes
21/2 '' (6.4 cm) beyond 24" (61.0 cm) base cabinet.
A. 13" (33.0 cm) upper cabinet depth
B. 30" (76.2 cm) min. opening width
C. For minimum clearance to the top of the cooktop,
see NOTE.
D. 231/4'' (59.1 cm) opening depth
E. 30" (76.2 cm) min. opening width
F. Electrical and gas supply - 5V2" (14.0 cm) min. from either cabinet,
10" (25.4 cm) max. from floor. Nothing located in shaded area can
extend more than 2¼" (5. 7 cm) from back wall or range will not slide
all the way back. Grounded outlet must be flush mounted.
G. Cabinet door or hinge should not extend into cutout.
H. 18" (45.7 cm)
I. 3" (7.6 cm) min. clearance from both sides of the range to the side
wall or other combustible
material.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is shielded by not less than 1/4"(0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.