Operating Limits
Power Output
Input Voltage
975-0263-01-01
The XM Series Inverter can deliver up to 1000 watts (XM 1000) or 1800
watts (XM 1800) continuous power. The wattage rating applies to
resistive loads such as incandescent lights.
The allowable XM Series Inverter input voltage ranges are shown in the
following table:
Operating
Condition
Normal
Optimum
Performance
Low Voltage Alarm
Low Voltage
Shutdown
High Voltage
Shutdown
Voltage Range
Comment
11–15.0 V
12.0–13.0 V
11.0 V or less
The low battery alarm beeps once
every two seconds and the display
shows fault code E01 alternating with
the battery voltage.
Less than
The low battery alarm beeps every
10.5 V
second and the display shows fault
code E02 alternating with the battery
voltage. The status LED turns red and
the inverter shuts down to protect the
battery from being over-discharged.
15.5 V or more
The over-voltage alarm beeps every
second and the display shows fault
code E03 alternating with the battery
voltage. The status LED turns red and
the inverter shuts down to protect
itself from excessive input voltage.
Note: Although the XM Series
Inverter incorporates over-voltage
protection, it can still be damaged if
input voltage exceeds 16 V.