A. Fuel Conversions
Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a qualifi ed
technician using Hearth & Home Technologies specifi ed and
approved parts.
1. Converting to LP Gas
NOTE: Gas conversions should only be performed
by a qualified service person, and/or where required
by state and local codes, licensed installer/service
technician. In the Commonwealth of Massachusetts,
installation must be performed by a licensed plumber
or gas fitter.
Kit Contents: Replacement orifi ce; replacement pilot
injector; valve regulator; conversion label.
Tools Required: Power drill (a 90° handle is helpful); #2
Phillips bit; 7/16" wrench; slotted screwdriver or Torx
TH20; 5/32 in. Allen wrench; 5/8 in. open end wrench.
Remove front (if installed), glass, and logs (if installed.)
Figure 6.1
Using the #2 Phillips screwdriver remove the two
(2) 1/4" x 20 screws securing the burner as indicated.
burner out of fi rebox.
22
Figure 6.2
left screw on the pilot tower, and removing the three
screws on the front side of the burner neck support.
Slide the burner neck support to the left.
Lift
Heat & Glo • TIARA II-B • 7011-148 Rev. D • 12/11
Loosen Left Screw
on Pilot Tower
Remove 3 Screws
Remove the burner support by loosening the
PILOT HOOD
MILLIVOT GENERATOR
Figure 6.3
Pull off pilot hood and set aside.
NOTE: Do not remove retaining clip from hood.