Heat & Glo RED40 Owner's Manual page 51

Natural gas
Hide thumbs Also See for Heat & Glo RED40:
Table of Contents

Advertisement

Figure 12.17. Fan Removal Through Firebox Bottom.
8. Remove mounting bracket from blower by removing the
six screws that hold the blower to the bracket. Two are
located on one side and four on the other side of the
bracket. Save the gasket for use with the new blower.
See Figure 12.18 and Figure 12.19.
Figure 12.18. Removal of Mounting Bracket from Blower.
Figure 12.19. Blower, Gasket Mounting Bracket, and Hardware.
Heat & Glo • RED40, RED40ST • 2155-900 Rev. F • 8/09
9. Attach new blower to mounting bracket by fastening the
six screws in the appropriate locations. The side of the
blower with the label on it must face toward the inside
of the appliance, or away from the air duct collar. This
is the direction of the air fl ow.
Figure 12.20. Proper Blower Orientation on Mounting Bracket.
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Red40st

Table of Contents