Heat & Glo RED40 Owner's Manual page 28

Natural gas
Hide thumbs Also See for Heat & Glo RED40:
Table of Contents

Advertisement

Top Vent - Vertical Termination
No Elbows
V
= 50 ft. Max. (15.2 m)
1
Note: If installing a vertical vent/termination off the top of the
appliance, the optional exhaust restrictor may be needed.
Note: Use DVP Series
components only.
V
1
Figure 7.7 Vertical Vent Maximum
Exhaust restrictors are recommended for these vertically
terminated products which have excessive draft. Exhaust
restrictors will compensate for high draft, and restore vi-
sual fl ame height. If the vent confi guration has a total ver-
tical of 20-50 feet, an exhaust restrictor may be needed.
The exhaust restrictor can be located in the appliance
manual bag.
28
Heat & Glo • RED40, RED40ST • 2155-900 Rev. F • 8/09
Exhaust restrictor Instructions
1. Locate the two pilot holes in the inside fi rebox cham-
ber as shown in Figure 7.8.
2. Center the exhaust restrictor such that the thru holes
in the vent restrictor align with the pilot holes in the
inner fi rebox chamber.
3. Use two 1/2 inch self-piercing screws to secure vent
restrictor to fi rebox heat shield. See Figure 7.8.
EXHAUST RESTRICTOR
Figure 7.8 Exhaust Restrictor
4. In some applications, such as those where the fi re-
place is elevated off the fl oor, the vent restrictor may
be painted, but painting is not required.
5. Recommended restrictor usage:
20 to 30 ft. = 4 inch restrictor
30 ft. and up = 3 inch restrictor
NOTICE: Before painting, contact your dealer for
information on the appropriate high temperature paint.