Solutions When The Interactive Pen Position Is Not Accurate; Solutions When Manual Calibration Is Difficult - Epson 1410Wi User Manual

Brightlink pro 1410wi
Table of Contents

Advertisement

Related references
Projector Setup Settings - Extended Menu
Related tasks
Using the Pens
Replacing the Pen Batteries
Calibrating Automatically
Calibrating Manually
Replacing the Pen Tips

Solutions When the Interactive Pen Position Is Not Accurate

If the pen position is not the same as the cursor, try the following solutions:
• Make sure you have calibrated the system. Try manual calibration.
• Make sure the cable cover is in place to keep cables from blocking the signal.
• Try adjusting the pen operation area.
• If you use the E-Zoom + button on the remote control to enlarge the image, the pen position is not
accurate. When you return the image to the original size, the position should be correct.
• Try changing the computer's resolution to 1280 × 800.
Parent topic:
Related tasks
Calibrating Automatically
Calibrating Manually
Adjusting the Pen Operation Area

Solutions When Manual Calibration is Difficult

If you are having trouble calibrating manually, try the following solutions:
• If the circle does not move to the next position, or it moves automatically, dim or turn off any bright
lights near the projection surface.
• Make sure the projector is not too close to the projection surface.
Parent topic:
Solving Interactive Problems