Figures 13 and 15 show a correct pilot flame pattern. The correct
flame will be blue and will extend beyond the thermocouple. The
flame will surround the thermocouple just below the tip. A slight
yellow flame may occur where the pilot flame and main burner
flame meet. Figures 14 and 16 show an incorrect pilot flame pattern.
The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the
heater will shut down.
VFp(32,36)Bp(30,31) pILOT
Correct Pilot Flame Pattern
Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 14
See Troubleshooting, page 21.