Battery replacement

If the server no longer automatically displays the correct date and time, you may need to replace the battery
that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING:
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
Power down the server (on page 6).
1.
Remove the access panel, and then pull out the motherboard tray.
2.
CAUTION:
remove all AC power cords before removing or installing the expansion boards.
Remove the battery.
3.
IMPORTANT:
configuration. After replacing the battery, reconfigure the system through BIOS Setup Utility.
The computer contains an internal lithium manganese dioxide, a vanadium
To prevent damage to the server or expansion boards, power down the server and
Replacing the system board battery resets the system ROM to its default
Battery replacement 72