Air Shutter Adjustment (If Necessary); Check Flame - Lopi GreenField Owner's Manual

Direct vent freestanding stove
Table of Contents

Advertisement

Installation
9.
Check the air shutter following the directions below.
Air Shutter Adjustment
Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The
flames should be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the
correct looking flame.
Correct
Flames should be blue at the
base, yellow-orange on the top.
Swing the control cover down to
access the air shutters.
10. Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox. Check the flame
on low position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis
dealer for a remedy.
11. Give this manual to the home owner for future reference and fully explain operation of this heater.
© Travis Industries
(for qualified installers only)
Not Enough Air
If the flames are too tall or sooty on the
ends, open the air shutter.
4101028
Too Much Air
If the flames are all blue and
short, close the air shutter.
Front Burner Air Shutter Control
Rear Burner Air Shutter Control
(GOLD)
Left = Less Air
Right = More Air
25
(RED)
Left = Less Air
Right = More Air
100-01255_000