Rear Vent Configuration With Vertical Termination - Lopi GreenField Owner's Manual

Direct vent freestanding stove
Table of Contents

Advertisement

20

Rear Vent Configuration with Vertical Termination

Use the rear vent conversion from
Travis Industries (SKU 94400998).
Use 8" Diameter Vent
Horizontal sections require a ¼"
(6mm) rise every 12" (305mm) of
travel.
A maximum of three (3) 45° or 90°
elbows may be used. Of these
elbows, only one (1) may be a
horizontal elbow (see illustration).
The termination must fall within the
shaded area shown in the chart.
Use the indicated restrictor position.
NOTE: Restrictor positions are
based upon lab tests. The ideal
restrictor position may vary slightly,
especially when the termination is
near a demarcation line
Horizontal Elbow
Horizontal elbows are elbows placed between
two horizontal sections of pipe. One 45° or 90°
horizontal elbow is allowed for this configuration.
© Travis Industries
Installation
(for qualified installers only)
31' max (9.3m)
30 feet (9m)
Exhaust Restrictor Position #4
Exhaust Restrictor Extender Installed
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
Exhaust Restrictor Position #3
Exhaust Restrictor Extender Installed
10 feet (3m)
5 feet (1.5m)
4101028
0 feet
100-01255_000
31' max (9.3m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet