7.0 Site Requirement
7.4

Gas Supply

1. The gas installation should be in accordance with the
relevant standards. In GB this is BS 6891 (Natural Gas) or
BS 5482-1 (Propane Gas). In IE this is the current edition of
I.S. 813 "Domestic Gas Installations".
2. A gas service cock is supplied to enable connection using
15mm copper pipe (Fig. 11).
3. Ensure that the pipework from the meter to the
appliance is of adequate size, and the demands of any
other gas appliances in the property are taken into
consideration. It is recommended that 22mm diameter
pipe is used to within 1m of the appliance.
7.5

Electrical Supply

1. External wiring must be correctly earthed, polarised and
in accordance with relevant regulations/rules. In GB this is
the current I.E.E. Wiring Regulations. In IE reference should
be made to the current edition of ETCI rules.
2. The mains supply is 230V ~ 50H z fused at 13A.
NOTE: The method of connection to the electricity
supply must facilitate complete electrical isolation of
the appliance.
Connection must be via a 13A BS1363 Switched Fuse
Spur servicing the boiler and system controls only.
NOTE: this appliance will not work in conjunction
with prepaid meters. Prepaid meters must be
replaced by the electricity provider to enable export
of electricity back into the grid.