10.0 Electrical
10.5
1. The appliance MUST have a permanent Live/Neutral/Earth
connection. The pump must be connected to the appliance as
shown.
2. Set parameter 5700 to '2' for one heating circuit - see section
11.3.k.
3. The DHW set point on the THINK Controller must be the
same as the thermostat set point on the cylinder. If this is not
done the DHW temperature may not be achieved or the
recovery time will be increased.
NOTE: It is not possible to operate a second heating circuit with
a Y-Plan system.