Replace DataTrak Battery or Fuse

The battery and fuse must be replaced in a
non-hazardous location.
Use only the following approved replacement batter-
ies. Use of an unapproved battery will void Graco's
warranty and FM and Ex approvals.
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Energizer alkaline # 522
Varta alkaline # 4922
Use only a Graco-approved replacement fuse. Order
Part 24C580.
Replace Battery
1. Unscrew cable from the back of the reed switch
assembly. See F
. 10.
IG
2. Remove the cable from the two cable clips.
F
. 10. Disconnect DataTrak
IG
3. Remove DataTrak module from bracket. See F
11. Take module and attached cable to a non-haz-
ardous location.
F
. 11. Remove DataTrak
IG
313255F
ti11992a
.
IG
ti11884a
4. Remove two screws on back of module to access
battery.
5. Disconnect the used battery and replace with an
approved battery. See F
Replace Fuse
1. Remove the screw, metal strap, and plastic holder.
2. Pull the fuse away from the board.
3. Replace with a new fuse.
Battery
F
. 12. DataTrak Battery and Fuse Location
IG
DataTrak Operation
. 12.
IG
Solenoid Cable
Connection
Fuse
Sensor Cable
Connection
ti11994a
23