Replace DataTrak Battery or Fuse

The battery and fuse must be replaced in a
non-hazardous location.
Use only the following approved replacement
batteries. Use of an unapproved battery will void
Graco's warranty and FM and Ex approvals.
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Energizer alkaline # 522
Varta alkaline # 4922
Use only a Graco-approved replacement fuse.
Order Part 24C580.
Replace Battery
1. Unscrew cable from the back of the reed switch
assembly. See F
. 18.
IG
2. Remove the cable from the two cable clips.
F
. 18. Disconnect DataTrak
IG
3. Remove DataTrak module from bracket. See F
19. Take module and attached cable to a
non-hazardous location.
F
. 19. Remove DataTrak
IG
3A1570V
4. Remove two screws on back of module to access
5. Disconnect the used battery and replace with an
Replace Fuse
1. Remove the screw, metal strap, and plastic holder.
2. Pull the fuse away from the board.
3. Replace with a new fuse.
ti11992a
.
IG
F
. 20. DataTrak Battery and Fuse Location
IG
ti18004a
battery.
approved battery. See F
Battery
Repair
. 20.
IG
Solenoid Cable
Connection
Fuse
Sensor Cable
Connection
ti11994a
41