Replace DataTrak Battery or Fuse

The battery and fuse must be replaced in a
non-hazardous location.
Use only the following approved replacement bat-
teries. Use of an unapproved battery will void
Graco's warranty and FM and Ex approvals.
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Energizer alkaline # 522
Varta alkaline # 4922
Use only a Graco-approved replacement fuse.
Order Part 24C580.
Replace Battery
1. Unscrew cable from the back of the reed switch
assembly. See F
. 16.
IG
2. Remove the cable from the two cable clips.
F
. 16. Disconnect DataTrak
IG
3. Remove DataTrak module from bracket. See F
17. Take module and attached cable to a non-haz-
ardous location.
F
. 17. Remove DataTrak
IG
3A1570L
4. Remove two screws on back of module to access
battery.
5. Disconnect the used battery and replace with an
approved battery. See F
Replace Fuse
1. Remove the screw, metal strap, and plastic holder.
2. Pull the fuse away from the board.
3. Replace with a new fuse.
ti11992a
.
IG
F
. 18. DataTrak Battery and Fuse Location
IG
ti18004a
. 18.
IG
Battery
Repair
Solenoid Cable
Connection
Fuse
Sensor Cable
Connection
ti11994a
39