Care Of The Spray Tip And Tip Guard - Graco 241705 Instructions-Parts List Manual

Texture airless spray gun b series
Table of Contents

Advertisement

Care of the Spray Tip and Tip Guard

WARNING
To reduce the risk of fluid injection or splashing in
the eyes or on the skin, do not hold a hand, body
or rag in front of the spray tip when cleaning or
checking a clogged tip. Point the gun toward the
ground or into a waste container when checking to
see if the spray tip is cleared.
Do not try to "blow back" paint; this is not an air
spray gun.
Do not wipe fluid buildup off the gun or spray tip
until pressure is relieved.
Cleaning during the day
WARNING
SKIN INJECTION HAZARD
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the Pressure Relief
Procedure on page 5.
1. Relieve pressure.
2. Clean the front of the tip frequently during the day
to help reduce buildup. Also clean the tip and tip
guard at the end of each work day. Use a solvent-
soaked brush to clean the spray tip.
Installation/Operation
If the spray tip clogs while spraying
1. Stop spraying immediately.
2. Lock the gun trigger safety. Rotate the RAC IV tip
handle back 180
. See Fig. 4.
_
3. Unlock the gun trigger safety. Trigger the gun into
a pail or onto the ground to remove the clog.
4. Lock the gun trigger safety. Rotate the tip handle
to the spraying position. See Fig. 4.
5. If the tip is still clogged, engage the gun trigger
safety, shut off the sprayer and disconnect the
power source, and open the pressure drain valve
to relieve pressure. Clean the spray tip as shown
in manual 308644, supplied with the RAC IV.
CAUTION
Never soak the entire gun in solvent. Prolonged
exposure to solvent can ruin the packings.
Spraying position shown.
1
Turn handle 180_ and
trigger gun to clear clog.
Fig. 4
1
03965
308491
7

Hide quick links: