Spray Tip And Tip Guard - Graco Roof Rigs 224483 Instructions-Parts List Manual

Gasoline powered airless sprayer 1200 psi (8.3 mpa, 83 bar) maximum working pressure
Table of Contents

Advertisement

WARNING
To reduce the risk of fluid injection or splashing in
the eyes or on the skin, completely relieve the fluid
pressure before installing, cleaning, or changing
tips. See the Pressure Relief Procedure on page
8.
Installation
1. Insert the housing through the back of the retaining
nut and pull it forward. See Fig. 7.
2. Install the metal seal in the housing, flat side first.
See Fig. 8.
3. Install the cylinder tip in the housing so its small ori-
fice faces front. See Fig. 9.
4. Snap on the tip guard. Install the screw and the white
gasket. See Fig. 10.
Operation
Be sure the tip arrow handle is in the FULL SPRAY posi-
tion before operating the gun. See Fig. 10.
WARNING
Keep clear of the nozzle. High pressure fluid from
leaks or spray can penetrate the skin and cause
extremely serious injury, including the need for
amputation. The tip guard provides extra protection
against injection, but does not prevent it. Never cut
off the tip guard.
Clearing a clogged spray tip
1. Engage the trigger safety latch.
2. Turn the arrow handle to the FULL CLEAN position.
3. Disengage the trigger safety latch and trigger the gun
into the waste container.
4. Engage the trigger safety latch. Return the arrow
handle to the FULL SPRAY position.
Maintenance
Replace the gasket and seal whenever you replace a tip;
these parts wear at about the same rate.

Spray Tip and Tip Guard

See Fig. 11.
HOUSING
RETAINING NUT
Fig. 7
RETAINING NUT
HOUSING
SEAL
Fig. 8
HOUSING
CYLINDER TIP
SMALL ORIFICE
Fig. 9
SCREW
TIP GUARD
Fig. 10
GUN NOZZLE
RAC IV
DripLess
TIP GUARD
SwitchTip
HANDLE
FULL SPRAY POSITION
Fig. 11
0464
0465
0466
GASKET
0467
FULL CLEAN POSITION
0093