Page 1
Includes GG0 series tip of choice Part No. 241469, Series A Acid Catalyzed Fluid Spray Gun Includes GG0 series tip of choice Part No. 233670, Series A Sealant Streaming Gun Read warnings and instructions. See page 2 for Table of Contents.
Page 2
Table of Contents Warnings ........Installation .
Page 3
INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury. D Fluid injected into the skin might look like just a cut, but it is a serious injury.
Install the gun on the manifold, using the four screws (17). Thread the screws by hand, then torque alter- nately and evenly to 65 in-lb (7.3 NSm). Models 233670 with Manifold 244930 This gun and manifold are designed to be used with high viscosity material and sealants, such as protective coatings and automotive sealants.
Mount the Gun Manifolds 241161 and 241162 To mount the gun on a reciprocating arm [0.5 in. (13 mm) diameter maximum], insert the bar (A) through the hole in the manifold as shown in Fig. 2. Secure the gun to the bar by tightening the mounting screw (B).
Air Line and Accessory Recommendations 1. Install an air pressure regulator on the gun cylinder air supply line. A minimum of 70 psi (0.49 MPa, 4.9 bar) air pres- sure must be supplied to the cylinder for proper operation. Air pressure opens the valve, a spring closes the valve.
Page 7
Manifolds 241161 and 241162 6. In a circulating system, connect an electrically conductive fluid hose to the gun fluid outlet (G). In a non-circulating system, remove the gun fluid outlet fitting (G) and plug the outlet port with the pipe plug (109) supplied. G (or F) ATOM Cylinder Air Inlet: accepts 1/4 in.
Ground the System WARNING FIRE AND EXPLOSION HAZARD Improper grounding could cause static sparking, which could cause a fire or explosion. To reduce the risk of property damage or serious injury, follow the grounding instructions below. The following grounding instructions are minimum requirements for a system.
(K). Screw the assembly firmly onto the gun. Tighten the assembly with a wrench. See Fig. 6. Fig. 6 NOTE: Gaskets are included with Streaming Tips 270XXX or Fan Tips 182XXX (used with Model 233670 Sealant Gun). 308813...
Page 10
Adjust Spray Pattern 1. To adjust the spray pattern direction with fan tips, orient the slot in the tip horizontally for a horizontal pattern and vertically for a vertical pattern. See Fig. 7. 2. Start the pump. Adjust the fluid pressure until the spray is completely atomized.
Flush the Gun Daily WARNING INJECTION HAZARD To reduce the risk of an injection injury, follow the Pressure Relief Procedure on page 9 before cleaning, removing, or installing a spray tip and whenever you are instructed to relieve pressure. WARNING To reduce the risk of serious injury, including splashing fluid in the eyes or on the skin, or static electric discharge when flushing:...
WARNING INJECTION HAZARD To reduce the risk of an injection injury, follow the Pressure Relief Procedure on page 9 before checking or servicing any of the system equipment and whenever you are instructed to relieve pressure. General Troubleshooting Problem Fluid leakage through venting holes.
WARNING INJECTION HAZARD To reduce the risk of an injection injury, follow the Pressure Relief Procedure on page 9 before checking or servicing any of the system equipment and whenever you are instructed to relieve pressure. General Troubleshooting (continued) Problem Fluid does not shut off.
Page 14
WARNING INJECTION HAZARD To reduce the risk of an injection injury, follow the Pressure Relief Procedure on page 9 before checking or servicing any of the system equipment and whenever you are instructed to relieve pressure. NOTE: D Follow the Service Notes in Figs. 8 and 9 when reassembling the gun.
Torque to 4–5 in-lb (0.45–0.56 NSm) Tighten cap (18) until it bottoms out Model 233670 gun uses a different tip (9), tip nut (7), and a gasket (8), and the seat (10) does not include a diffuser. Model 233670 gun does not include items 4, 5, 6, 8, 9, and 32.
Page 16
Fig. 9 308813 Service Model 233670 gun uses a different tip (9), tip nut (7), and a gasket (8), and the seat (10) does not include a diffuser. Model 233670 gun does not include items 4, 5, 6, 8, 9, and 32.
Page 17
Screw the assembly firmly onto the gun. Tighten the assembly with a wrench, but do not exceed 5 ft–lb (6.8 NSm) for model 233670 gun. 14. Reinstall the gun on the manifold with the four screws (14). Torque to 65 in-lb (7.3 NSm).
Page 18
M5 x 0.8; 45 mm long 114136 SCREW, cap, socket head; M5 x 0.8; 20 mm long 308813 Parts Part No. 233670, Series A Automatic Sealant Stream/Spray Gun Includes items 1–3, 7, 10–31, 34 114137 SCREW, set; 6–32; 1/8 in. long Qty.
Page 19
Part No. 239786 shown Parts 12 (Ref) Model 233670 gun uses a different tip (9), tip nut (7), and a gasket (8), and the seat (10) does not include a diffuser. Model 233670 gun does not include items 4, 5, 6, 8, 9, and 32.
Page 20
Use Only Genuine Graco Parts and Accessories Part No. 241161, Series A North America Manifold Part No. 241162, Series A International Manifold Ref. Part No. Description 239892 MANIFOLD 113208 FITTING, tube, air inlet; 1/4 in. (6.3 mm) OD tube x 1/8 npt(m) 114246 SCREW, set;...
Sealer Application Tip Selection Charts For Model 233670 with tip nut 198391 Shower Tip No. of Orifices Orifice Size inches (mm) 0.021 (0.533) Single Orifice Fan Pattern Spray Tips Fan Width Fan Width Orifice Orifice at 12 at 12” Size (300 mm) 0.021...
Page 27
Use Only Genuine Graco Parts and Accessories GUN MANIFOLDS Order separately; not included with gun (See page 20 for Parts list) Part No. 241161, Series A North America Manifold Part No. 241162, Series A International Manifold Part No. 244930, Series A High Flow Ambient or Temperature Conditioned Man- ifold for streaming or spraying Grounding Clamp and Wire 222011...
Maximum working fluid pressure ... . Maximum working air pressure ... . . Maximum working fluid temperature ..Minimum air cylinder actuation pressure .
Page 30
Dimensions and Mounting Holes For Guns 239786 and 241469 with Manifolds 241161 and 241162 2.0 in. (50.8 mm) 3.86 in. (98.0 mm) 0.805 in. (20.5 mm) 0.187 in. (4.8 mm) 308813 5.23 in. (139.7 mm) 3.0 in. (76.2 mm) 0.4 in. (10.2 mm) Two M5 x 0.8 x 0.25 in.
Page 31
Dimensions and Mounting Holes For Model 233670 2.25 in. (57.2 mm) 0.805 in. (20.4 mm) 1.375 in. (35 mm) 0.437 in. (11.1 mm) 0.4 in. (10.2 mm) 4.8 in. (121.9 mm) 3.5 in. (88.9 mm) 1.25 in. (32 mm) 2.13 in.
Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.