CIRCULATING, HIGH PRESSURE
Automatic Airless
Spray Gun
4000 psi (28 MPa, 280 bar) Maximum Working Fluid Pressure
Part No. 239786, Series A
Standard Spray Gun
Includes GG0 series tip of choice
Part No. 241469, Series A
Acid Catalyzed Fluid Spray Gun
Includes GG0 series tip of choice
Part No. 233670, Series A
Sealant Streaming Gun
Read warnings and instructions.
See page 2 for Table of Contents.
308813J

Advertisement

Table of Contents
loading

Summary of Contents for Graco 233670

  • Page 1 Includes GG0 series tip of choice Part No. 241469, Series A Acid Catalyzed Fluid Spray Gun Includes GG0 series tip of choice Part No. 233670, Series A Sealant Streaming Gun Read warnings and instructions. See page 2 for Table of Contents.
  • Page 2 Table of Contents Warnings ........Installation .
  • Page 3 INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury. D Fluid injected into the skin might look like just a cut, but it is a serious injury.
  • Page 4: Installation

    Install the gun on the manifold, using the four screws (17). Thread the screws by hand, then torque alter- nately and evenly to 65 in-lb (7.3 NSm). Models 233670 with Manifold 244930 This gun and manifold are designed to be used with high viscosity material and sealants, such as protective coatings and automotive sealants.
  • Page 5: Mount The Gun

    Mount the Gun Manifolds 241161 and 241162 To mount the gun on a reciprocating arm [0.5 in. (13 mm) diameter maximum], insert the bar (A) through the hole in the manifold as shown in Fig. 2. Secure the gun to the bar by tightening the mounting screw (B).
  • Page 6: Air Line And Accessory Recommendations

    Air Line and Accessory Recommendations 1. Install an air pressure regulator on the gun cylinder air supply line. A minimum of 70 psi (0.49 MPa, 4.9 bar) air pres- sure must be supplied to the cylinder for proper operation. Air pressure opens the valve, a spring closes the valve.
  • Page 7 Manifolds 241161 and 241162 6. In a circulating system, connect an electrically conductive fluid hose to the gun fluid outlet (G). In a non-circulating system, remove the gun fluid outlet fitting (G) and plug the outlet port with the pipe plug (109) supplied. G (or F) ATOM Cylinder Air Inlet: accepts 1/4 in.
  • Page 8: Ground The System

    Ground the System WARNING FIRE AND EXPLOSION HAZARD Improper grounding could cause static sparking, which could cause a fire or explosion. To reduce the risk of property damage or serious injury, follow the grounding instructions below. The following grounding instructions are minimum requirements for a system.
  • Page 9: Operation

    (K). Screw the assembly firmly onto the gun. Tighten the assembly with a wrench. See Fig. 6. Fig. 6 NOTE: Gaskets are included with Streaming Tips 270XXX or Fan Tips 182XXX (used with Model 233670 Sealant Gun). 308813...
  • Page 10 Adjust Spray Pattern 1. To adjust the spray pattern direction with fan tips, orient the slot in the tip horizontally for a horizontal pattern and vertically for a vertical pattern. See Fig. 7. 2. Start the pump. Adjust the fluid pressure until the spray is completely atomized.
  • Page 11: Flush The Gun Daily

    Flush the Gun Daily WARNING INJECTION HAZARD To reduce the risk of an injection injury, follow the Pressure Relief Procedure on page 9 before cleaning, removing, or installing a spray tip and whenever you are instructed to relieve pressure. WARNING To reduce the risk of serious injury, including splashing fluid in the eyes or on the skin, or static electric discharge when flushing:...
  • Page 12: General Troubleshooting

    WARNING INJECTION HAZARD To reduce the risk of an injection injury, follow the Pressure Relief Procedure on page 9 before checking or servicing any of the system equipment and whenever you are instructed to relieve pressure. General Troubleshooting Problem Fluid leakage through venting holes.
  • Page 13: Spray Pattern Troubleshooting

    WARNING INJECTION HAZARD To reduce the risk of an injection injury, follow the Pressure Relief Procedure on page 9 before checking or servicing any of the system equipment and whenever you are instructed to relieve pressure. General Troubleshooting (continued) Problem Fluid does not shut off.
  • Page 14 WARNING INJECTION HAZARD To reduce the risk of an injection injury, follow the Pressure Relief Procedure on page 9 before checking or servicing any of the system equipment and whenever you are instructed to relieve pressure. NOTE: D Follow the Service Notes in Figs. 8 and 9 when reassembling the gun.
  • Page 15: Cutaway View

    Torque to 4–5 in-lb (0.45–0.56 NSm) Tighten cap (18) until it bottoms out Model 233670 gun uses a different tip (9), tip nut (7), and a gasket (8), and the seat (10) does not include a diffuser. Model 233670 gun does not include items 4, 5, 6, 8, 9, and 32.
  • Page 16 Fig. 9 308813 Service Model 233670 gun uses a different tip (9), tip nut (7), and a gasket (8), and the seat (10) does not include a diffuser. Model 233670 gun does not include items 4, 5, 6, 8, 9, and 32.
  • Page 17 Screw the assembly firmly onto the gun. Tighten the assembly with a wrench, but do not exceed 5 ft–lb (6.8 NSm) for model 233670 gun. 14. Reinstall the gun on the manifold with the four screws (14). Torque to 65 in-lb (7.3 NSm).
  • Page 18 M5 x 0.8; 45 mm long 114136 SCREW, cap, socket head; M5 x 0.8; 20 mm long 308813 Parts Part No. 233670, Series A Automatic Sealant Stream/Spray Gun Includes items 1–3, 7, 10–31, 34 114137 SCREW, set; 6–32; 1/8 in. long Qty.
  • Page 19 Part No. 239786 shown Parts 12 (Ref) Model 233670 gun uses a different tip (9), tip nut (7), and a gasket (8), and the seat (10) does not include a diffuser. Model 233670 gun does not include items 4, 5, 6, 8, 9, and 32.
  • Page 20 Use Only Genuine Graco Parts and Accessories Part No. 241161, Series A North America Manifold Part No. 241162, Series A International Manifold Ref. Part No. Description 239892 MANIFOLD 113208 FITTING, tube, air inlet; 1/4 in. (6.3 mm) OD tube x 1/8 npt(m) 114246 SCREW, set;...
  • Page 21: Gg0 Series Tip Selection Charts

    GG0 Series Tip Selection Charts GG0 Series Spray Tips Flow Rate Flow Rate Orifice Fan Width (tested in Size Size at 12” at 12” water) water) inches inches (300 mm) (300 mm) gal/min gal/min (mm) Inches (mm) (liters/min) 2–2.5 0.007 .053 (0.178) (50–63)
  • Page 22 GG0 Series Tip Selection Charts GG0 and GG1 Series Spray Tips Orifice Orifice Fan Width Fan Width Flow Rate Flow Rate Size 0.019 2–2.5 0.39 (50–63) (0.483) (1.47) 4–4.5 (100–113) 6–6.5 (150–163) 8–8.5 (200–213) 10–10.5 (250–263) 12–13 (300–325) 14–15 (350–375) 16–17 (400–425) 18–19...
  • Page 23 GG0 Series Tip Selection Charts GG0 and GG1 Series Spray Tips Orifice Orifice Fan Width Fan Width Flow Rate Flow Rate Size 0.031 4–4.5 1.03 (100–113) (0.787) (3.90) 6–6.5 (150–163) 8–8.5 (200–213) 10–10.5 (250–263) 12–13 (300–325) 14–15 (350–375) 16–17 (400–425) 18–19 (450–475) 0.033...
  • Page 24 GG0 Series Tip Selection Charts GG0 and GG1 Series Spray Tips Orifice Orifice Fan Width Fan Width Flow Rate Flow Rate Size 0.045 8–8.5 2.17 (200–213) (1.143) (8.23) 10–10.5 (250–263) 12–13 (300–325) 16–17 (400–425) 24–25 (600–625) 0.047 10–10.5 2.37 (1.194) (250–263) (8.98) 12–13...
  • Page 25 GG0 Series Tip Selection Charts GG0 and GG1 Series Spray Tips Orifice Orifice Fan Width Fan Width Flow Rate Flow Rate Size 0.065 8–8.5 4.53 (200–213) (1.65) (17.2) 10–10.5 (250–263) 12–13 (300–325) 14–15 (350–375) 16–17 (400–425) 8–8.5 0.067 4.82 (1.70) (200–213) (18.2) 10–10.5...
  • Page 26: Shower Tip

    Sealer Application Tip Selection Charts For Model 233670 with tip nut 198391 Shower Tip No. of Orifices Orifice Size inches (mm) 0.021 (0.533) Single Orifice Fan Pattern Spray Tips Fan Width Fan Width Orifice Orifice at 12 at 12” Size (300 mm) 0.021...
  • Page 27 Use Only Genuine Graco Parts and Accessories GUN MANIFOLDS Order separately; not included with gun (See page 20 for Parts list) Part No. 241161, Series A North America Manifold Part No. 241162, Series A International Manifold Part No. 244930, Series A High Flow Ambient or Temperature Conditioned Man- ifold for streaming or spraying Grounding Clamp and Wire 222011...
  • Page 28: Technical Data

    Maximum working fluid pressure ... . Maximum working air pressure ... . . Maximum working fluid temperature ..Minimum air cylinder actuation pressure .
  • Page 29 Notes 308813...
  • Page 30 Dimensions and Mounting Holes For Guns 239786 and 241469 with Manifolds 241161 and 241162 2.0 in. (50.8 mm) 3.86 in. (98.0 mm) 0.805 in. (20.5 mm) 0.187 in. (4.8 mm) 308813 5.23 in. (139.7 mm) 3.0 in. (76.2 mm) 0.4 in. (10.2 mm) Two M5 x 0.8 x 0.25 in.
  • Page 31 Dimensions and Mounting Holes For Model 233670 2.25 in. (57.2 mm) 0.805 in. (20.4 mm) 1.375 in. (35 mm) 0.437 in. (11.1 mm) 0.4 in. (10.2 mm) 4.8 in. (121.9 mm) 3.5 in. (88.9 mm) 1.25 in. (32 mm) 2.13 in.
  • Page 32: Graco Standard Warranty

    Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.