Operation

Reset

Whites Setting

White Calibration

-12-
Continued from previous page
This setting allows the user to reset the COLORado™ 1 IP fixture to its default values,
including the custom programs.
1) Go to SET> REST.
2) When prompted, enter the master access password as shown in Control Panel
Lock.
3) Wait for the reset process to finish.
This setting allows the user to edit the temperature of the 11 white colors used in the
Macros channel. The 11 pre-set whites are configurable.
1) Go to CAL1.
2) Select a white color (WT. 1~11).
3) Select a color (Red, Green, Blue, or White).
4) Select a color value (0~255).
5) Repeat for the other colors (Red, Green, Blue, or White).
6) Repeat for the other white colors (WT. 1~11).
This setting allows the user to select the white color shown by the COLORado™ 1 IP
when the color setting is RGBW and the Red, Green, and Blue faders are set to "255".
1) Go to CAL2 > RGBW.
2) Select a color (Red, Green, or Blue).
3) Select a color value (0~255).
4) Repeat for the other colors (Red, Green, or Blue).