The PC 45 Multi-fuel Stove makes burning corn, pellets, or grain more convenient than ever. It's special Sidewinder
Burn Pot allows corn to be burned from three days up to a week without cleaning, depending on the corn's moisture
level and burn rate.
Automatic Ignition allows you to fill the hopper, set your desired room temperature and walk away. The PC 45 will adjust
it's feed rate based on the temperatures received by the room sensor, and keep your home at the set temperature.
The PC 45's automatic temperature control system eliminates the warm/cold cycle associated with thermostatically
controlled heating systems and even turns the PC 45 on and off as needed.
Our exclusive Accordion Heat Exchanger and Air Cooled Combustion Blower allows the PC 45 to produce maximum
heat without creating high exhaust temperatures. The Outside Air option can increase heat efficiency even more.
The PC 45 can burn corn or grain with moisture levels up to 16%, with 14.5% or less being ideal. It can also burn
pellets regardless of ash content. This allows you to buy lower cost fuel and still achieve the same results.
P l e a s e c o p y y o u r
serial number from
the label on your stove
to the box below.
SErIAl NumbEr
SAFETY NOTICE: IF THIS HARMAN STOVE IS NOT PROPERLY
INSTALLED. A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY,
FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
AlwAYS bE SurE ThErE IS NO FuEl IN ThE ASh PAN
PrIOr TO burNINg ThE STOvE. AFTEr ANY SErvICE
Or TESTINg, EmPTY ThE ASh PAN COmPlETElY.
ThIS APPlIANCE IS AlSO APPrOvEd FOr INSTAllA-
TION IN A ShOP.
harman home heating
352 mountain house road
halifax, PA 17032
www.harmanstoves.com
Introduction
Harman PC 45 Corn/Pellet Stove
Label measures: 4.5"high x 11 7/8"wide
LISTED CORN/PELLET FUEL BURNING ROOM HEATER
MODEL: PC 45
C
US
WHI -
W/N 10941
TESTED TO : UL 1482
DO NOT REMOVE THIS LABEL.
NE PAS ENLEVER CETTE ÉTIQUETTE.
ASTM E1509
OREGON 814-23-900
CORNER INSTALLATION 9" WITH
ULC-S627
WH-PN 025
TEST DATE: MARCH 1998
WITHOUT
WITH
MINIMUM CLEARANCES
SIDE SHIELDS
SIDE SHIELDS
TO COMBUSTIBLES:
SIDEWALL TO STOVE
18"
12"
BACKWALL TO STOVE
2"
2"
CEILING TO STOVE TOP
20"
20"
STOVE CORNER TO DIAGONAL WALL
13"
9"
PREVENT HOUSE FIRES, OPERATE WITH VIEWING & ASH DOOR CLOSED.
UNIT MUST BE PLACE ON A NON-COMBUSTIBLE FLOOR PROTECTOR EX-
TENDING 6" TO THE FRONT, 6" TO SIDES AND 1" TO REAR.
EXHAUST TYPE: LISTED TYPE L OR PL VENT INSTALLED TO VENT MANU-
FACTURER'S INSTRUCTIONS AND LOCAL BUILDING CODES.
ELECTRICAL RATING: 6 AMPS, 120 VOLTS, 60 HERTZ
FUEL: PELLETIZED OR BIOMASS
INSTALL AND USE ONLY IN ACCORDANCE WITH MANUFACTURER'S INSTAL-
LATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR
FIRE OFFICIALS ABOUT RESTRICTIONS & INSTALLATION INSPECTION IN
YOUR AREA.
EPA EXEMPT PER 40 CFR 60.534, METHOD 28A.
APPROVED FOR USE IN MOBILE HOMES.
INPUT RATING: 0 TO 5.0 LBS PER HOUR.
DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING
ANOTHER APPLIANCE
ESPACES LIBRES MINIMUM
INSTALL WITH MINIMUM
DES MATÉRIAUX COMBUSTIBLES:
CLEARANCES TO WALLS AS
DU MÛR DE CÔTÉ AU POÊLE
SHOWN
DU MÛR ARRIÈRE AU POÊLE
SIDEWALL-BACkWALL
DU PLAFOND AU DESSUS DU POÊLE
OR 13" WITHOUT
INSTALLATION WITH
DU COIN DU POÊLE AU MÛR DIAGONAL
SIDE SHIELDS
SIDE SHIELDS
PRÉVENIR LES FEUX DE MAISONS. OPÉRER SEULEMENT AVEC LA PORTE
2"
9-13"
D'OUVERTURE ET LA PORTE DES CENTRES FERMÉES. L'APPAREIL DOIT
ÊTRE PLACÉ SUR UN PLANCHER PROTECTEUR INCOMBUSTIBLE, CELUI-CI
S'ÉTENDANT DE 6" EN AVANT, DE 6" DES CÔTÉS ET D 1" DE L'ARRIÈRE.
12"
SORTE D'ÉCHAPPEMENT: VENTILATEUR DE TYPE L OU PL INSTALLÉ SELON
9-13"
LES INSTRUCTIONS DU FABRICANT ET SELON LES CODES LOCAUX DE
LA CONSTRUCTION.
PUISSANCE ÉLECTRIqUE: 6 AMPS, 120 VOLTES, 60 HERTZ
SIDEWALL-BACkWALL
COMBUSTIBLE: DE BOULETTES COMBUSTIBLES OU BIOMASSES.
FLOOR PROTECTOR
INSTALLATION WITHOUT
INSTALLER ET UTILISER SELON LES INSTRUCTIONS D'INSTALLATION ET
SIDE SHIELDS
MINIMUM SIzE
1"
D'OPÉRATION DE FABRICANT. CONTACTER LE BUREAU DE LA CONSTRUC-
2"
TION OU LE BUREAU DES POMPIERS AU SUJET DES RESTRICTIONS ET
DES INSPECTIONS D'INSTALLATION DANS VOTRE VOISINAGE.
EXEMPTION EPA PAR 40 CFR 60.534, DE MÉTHODE 28a
6"
6"
18"
APPROUVÉ POUR L'USAGE DANS LES MAISONS MOBILES
PUISSANCE ESTIMÉE: 0 À 5.0 LBS PAR HEURE.
6"
MANUFACTURED BY:
HARMAN STOVE COMPANY
352 MOUNTAIN HOUSE ROAD
HALIFAX, PA 17032
MADE IN USA
Table of Contents
Assembly & Installation
Installation
venting
grain Cap Installation
Pellet Fuel Optimization
Automatic Operation
ESP Control
maintenance
Troubleshooting
Fuel Specifications
Options
wiring diagram
warranty
Service Parts
Power Failure / back-up
APPAREIL DE CHAUFFAGE CATALOGUÉ DE
MODÈLE POUR BRÛLER DES MAIS/BOULETTES COMBUSTIBLES.
MODÈLE: "PC 45"
AVEC LES
SANS LES
INSTALLER AVEC LES DISTANCES
PROTECTEURS
PROTECTEURS
DE CÔTÉ
DE CÔTÉ
MINIMUM DE SECURITÉ COMME
18"
12"
INDIqUÉ.
2"
2"
INSTALLATION EN ANGLE 9" AVEC
20"
20"
OU 13" SANS PROTECTIONS
13"
9"
MURALES
9-13"
9-13"
TAILLE MINIMALE
DE LA PROTECTION DE SOL.
1"
6"
6"
6"
NE PAS CONNECTER CET APPAREIL À
UNE CHEMINÉE SERVANT UN AUTRE
APPAREIL.
13
14
15
19
21
24
25
27
29
30
32
37
PC 45 Corn/Pellet Stove
DISTANCES AUX MURS
LATÉRAL ET ARRIÈRE AVEC
PROTECTIONS MURALES
2"
12"
DISTANCES AUX MURS
LATÉRAL ET ARRIÈRE SANS
PROTECTIONS MURALES
2"
18"
4
5
6
3