Fireplace Installation Using Standard Surround Kits
(P/N 79004, 79005, 79006 and 79007)
11"
19-1/4"
138°
6-11/16"
Figure 11B
Fireplace Installation Using 3 Inch Deep ZC Surround Kit
13-1/2"
11"
21-1/2"
138°
6-11/16"
* This black surround kit positions the insert 3" forward so that it will allow the insert to fit
into a fireplace with a narrower width in the front (32" min.). Note: No trim kits are avail-
able for this kit at this time. See instruction sheet P/N 506033-05 for more information.
Figure 11C
FIREPLACE OPENING C/L
36" FIREPLACE OPENING
18"
13-1/2"
41" SURROUND WIDTH
HEARTH / FLOOR PROTECTION
31-3/4"
18-3/8"
(P/N H73 *)
FIREPLACE OPENING C/L
32" FIREPLACE OPENING
18"
41" SURROUND WIDTH
HEARTH/FLOOR PROTECTION
31-3/4"
18-3/8"
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Manufactured (Mobile) Home Installations
The following steps are required for installation of the Winslow™
PI40 insert in mobile homes. See Figure 12.
• Installation should be in accordance with the Manufactured
Home and Safety Standard (HUD), CFR 3280, Part 24.
• Connecting the Winslow PI40 insert to outside combustion
air is optional, except in mobile home installations and when
required by local building codes. The insert's air intake will
accept 2" ID pipe to accommodate outside air installations.
The air intake on the exterior of the home should always be
located substantially below the flue termination and must
remain free of obstruction. The inlet must also have a screen
with openings not larger than 1/4" to prevent rodents from
2-15/16"
entering.
• The insert must be fastened to the hearth/floor using lag
CONTROL BOARD
screws. The screws can be inserted through the holes in
the base located behind the side doors. If the hearth is
concrete or masonry, use proper lag bolts and methods
designed for anchoring to masonry or concrete.
• The insert must be grounded with a #8 or larger copper
wire.
WARNING: DO NOT INSTALL THIS INSERT IN A SLEEP-
ING ROOM IN A MANUFACTURED HOME.
CAUTION: THE STRUCTURAL INTEGRITY OF THE
7-7/16"
MANUFACTURED HOME FLOOR, WALL, AND CEIL-
ING/ROOF MUST BE MAINTAINED.
Termination Cap
Outside Air Pipe
3"
Listed Pellet Pipe or
DEEP
CONTROL
Flex Liner
BOARD
SURROUND
7-7/16"
Figure 12
Storm Collar
Flashing
11