LENNOX HEARTH PRODUCTS • RHAPSODY™ LINEAR DIRECT-VENT GAS FIREPLACES (MODELS RHAP42N & RHAP54N) • INSTALLATION INSTRUCTIONS
gENERAL
INfORMATION

INTROdUCTION

LENNOX HEARTH PRODUCTS Rhapsody™
model fireplaces are direct-vent (top vent
only), sealed combustion, air-circulating gas
fireplaces designed for residential, manufac-
tured home and commercial applications.
Direct-vent appliances operate with the com-
bustion chamber isolated from the indoor
environment. All air for combustion is brought
in from the outside, and exhaust gases are
vented through the same direct-vent, coaxial
(intake/exhaust) vent system.
These appliances are designed to operate
on natural or propane gas only. The use of
other fuels or fuel combinations will degrade
the performance of this system, may be
dangerous, and may void the warranty.
The electronic system is switchable between
standing and intermittent pilot modes (see
Figure 15).
The Total Comfort Control™ Remote Control
System is included with all models and provides
remote operation of several fireplace functions
(manual adjustment of the gas valve settings is
not possible). See Page 26 for details.
Electrical power (120V AC line voltage) is rec-
ommended to operate the fireplace; however,
"AA" batteries can be used for full-time opera-
tion or as a backup in case of a power outage.
Note: Batteries will operate the gas valve
OPEN/CLOSE and pilot ON/OFF functions
only. Electrical power (120V AC line volt-
age) is required to operate the following
optional components (bat teries will not
power any of these options):
• Blower Kit
• Power Vent System
• Panel Backlighting Kit

EffICIENCIES

EffICIENCIES
Natural gas
fireplace
Model
Energuide
AfUE*
(P4)
RHAP42N
67%
61%
RHAP54N 70.2%
66.9%
*AFUE (Annual Fuel Utilization Efficiency) is the
recognized U.S. rating system for the total effi-
ciency of heating products.
Table 1
4

LISTINg INfORMATION

These appliances comply with National Safety
Standards and are tested and listed by Intertek
(Report No. 100404899PRT-001) to ANSI
Z21.88 (in Canada, CSA-2.33), and CAN/CGA-
2.17-M91 (CSA P4.1) in both USA and Canada,
as vented gas fireplace heaters.
These appliances are listed by Intertek for
installation in bedrooms, aftermarket mobile
homes, and manufactured homes.

COdES

Installation must conform to local codes or, in
the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, latest
edition (in Canada, the current CAN/CGA-
B149.1 installation code).
The appliance, when installed, must be electri-
cally grounded and wired in accordance with
local codes, or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA
70, latest edition, or the Canadian Electrical
Code, CSA C22.1, latest edition.
MANUfACTUREd HOME
REqUIREMENTS
This appliance may be installed in an aftermar-
ket permanently located, manufactured home
and must be installed in accordance with the
manufacturer's instructions.
Cet appareil peut être installé cómme du
matéri-el d'origine dans une maison préfab-
riquée (É.U. seulement) ou mobile et doit être
installé selon les instructions du fabricant.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
Cet appareil doit être utilisé uniquement
avec le type de gaz indiqué sur la plaque
signalétique. Cet appareil ne peut être con-
verti à d'autres gaz, sauf si une trousse de
conversion est utilisée.
CAUTION: Ensure that the cross mem-
bers are not cut or weakened during
installation. The structural integrity of
Propane
the manufactured home floor, wall, and
(field-converted)
ceiling / roof must be maintained.
Energuide
AfUE*
(P4)
CAUTION: This appliance must be ground-
68.5%
66%
ed to the chassis of the manufactured
69.8%
71.8%
home in accordance with local codes or
in the absence of local codes, with the
National Electrical Code ANSI / NfPA 70
- latest edition or the Canadian Electrical
Code CSA C22.1 - latest edition.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
REqUIREMENTS fOR COMMON-
WEALTH Of MASSACHUSETTS
These fireplaces are approved for installation in
the US state of Massachusetts if the following
additional requirements are met:
• Install appliance in accordance with Massa-
chusetts Rules and Regulations 248 C.M.R.
• Installation and repair must be done by a
plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
• The flexible gas-line connector used shall
not exceed 36 inches (92 centimeters) in
length.
• The individual manual shutoff must be a
T-handle type valve.
Massachusetts Horizontal Vent
Requirements
In the Commonwealth of Massachusetts, hori-
zontal terminations installed less than seven
(7) feet above the finished grade must comply
with the following additional requirements:
• A hard-wired carbon monoxide detector
with an alarm and battery backup must be
installed on the floor level where the gas
fireplace is installed. The carbon monoxide
detector must comply with NFPA 720, be
ANSI/UL 2034 listed and be ISA certified.
• A metal or plastic identification plate must
be permanently mounted to the exterior of
the building at a minimum height of eight (8)
feet above grade and be directly in line with
the horizontal termination. The sign must
read, in print size no less than one-half (1/2)
inch in size: GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS.
COLd CLIMATE INSULATION
REqUIREMENTS
For cold climate installations:
• Use noncombustible caulk to seal all joints
around the appliance and wherever cold air
could enter the room.
• Caulk all gas-line holes and other openings
(or stuff with unfaced fiberglass insulation).
• Caulk firestops only where pipe penetrates
an outside wall, attic, or other other uncon-
ditioned space.
• If the floor is above ground level, insulate
the outside chase cavity between the studs
and under the floor beneath the appliance.
• If installing the fireplace on a cement slab,
place a sheet of plywood or other raised
platform underneath to prevent cold transfer
to the fireplace and into the room.
• Drywall and tape all inside sur faces of sur-
rounding chase for maximum air tightness.

Hide quick links: