Fireplace Installation Using Standard Surround Kits
(P/N 79004, 79005, 79006 and 79007)
11"
19-1/4"
138°
6-11/16"
Figure 11B
Fireplace Installation Using 3 Inch Deep ZC Surround Kit
11"
21-1/2"
138°
6-11/16"
* This black surround kit positions the insert 3" forward so that it will allow the insert to fit
into a fireplace with a narrower width in the front (32" min.). Note: No trim kits are avail-
able for this kit at this time. See instruction sheet P/N 506033-05 for more information.
Figure 11C
12
FIREPLACE OPENING C/L
36" FIREPLACE OPENING
18"
13-1/2"
41" SURROUND WIDTH
HEARTH / FLOOR PROTECTION
31-3/4"
18-3/8"
(P/N H7232 *)
FIREPLACE OPENING C/L
32" FIREPLACE OPENING
18"
13-1/2"
41" SURROUND WIDTH
HEARTH/FLOOR PROTECTION
31-3/4"
18-3/8"
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Manufactured (Mobile) Home Installations
In addition to the standard installation instructions, the fol-
lowing instructions may be required by local, state or federal
building codes. See Figure 12.
• Installation should be in accordance with the Manufactured
Home and Safety Standard (HUD), CFR 3280, Part 24.
• Connecting the Winslow PI40 insert to outside combustion
air is required in manufactured home installations and when
required by local building codes. The insert's air intake will
accept 2" ID pipe to accommodate outside air installations.
The air intake on the exterior of the home should always
be located a minimum of 18" below the flue termination
and must remain free of obstruction. The inlet must also
2-15/16"
have a screen with openings not larger than 1/4" to prevent
rodents from entering.
CONTROL BOARD
• The insert must be fastened to the hearth/floor using lag
screws. The screws can be inserted through the holes in
the base located behind the side doors. If the hearth is
concrete or masonry, use proper lag bolts and methods
designed for anchoring to masonry or concrete.
• The insert must be grounded with a #8 or larger copper
wire.
WARNING: DO NOT INSTALL THIS INSERT IN A SLEEP-
ING ROOM IN A MANUFACTURED HOME.
7-7/16"
CAUTION: THE STRUCTURAL INTEGRITY OF THE
MANUFACTURED HOME FLOOR, WALL, AND CEIL-
ING/ROOF MUST BE MAINTAINED.
Termination Cap
Outside Air Pipe
3"
Listed Pellet Pipe or
DEEP
CONTROL
Flex Liner
BOARD
SURROUND
7-7/16"
Figure 12
Storm Collar
Flashing